VDE 0482-266-2-1 : 2001

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - PART 2-1: PROCEDURES - CATEGORY A F/R

Withdrawn date

01-08-2010

Published date

12-01-2013

Einleitung
1 Anwendungsbereich
2 Normative Verweisungen
3 Begriffe
4 Prüfvorrichtung
  4.1 Allgemeines
  4.2 Zündquelle
5 Prüfverfahren
  5.1 Probe
  5.2 Bestimmung der Anzahl von Probestücken
  5.3 Befestigung der Probe
  5.4 Dauer der Beflammung
6 Auswertung der Prüfergebnisse
7 Leistungsanforderungen
8 Wiederholungsprüfung
9 Prüfbericht
Anhang A (normativ) Regel für Auswahl der Kabel für die
         Typprüfung
Anhang B (informativ) Empfohlene Leistungsanforderungen

EN 50266 legt Prüfverfahren für die Bewertung der Brandausbreitung unter definierten Bedingungen senkrecht befestigter, gebündelter, elektrischer oder optischer Leitungen oder Kabel fest. ANMERKUNG Für die Anwendung dieser Norm umfasst der Begriff "elektrische Leitung oder Kabel" alle Kabel mit isolierten Metallleitern für die Übertragung von Energie oder Signalen. Die Prüfung ist als Typprüfung vorgesehen. Die Anforderungen für die Auswahl der zu prüfenden Kabel sind in Anhang A festgelegt. Die Flammenausbreitung wird als Länge der Beschädigung der Kabelprobe gemessen. Das Verfahren kann verwendet werden, um die Fähigkeit des Kabels, die Flammenausbreitung zu begrenzen, zu beweisen. Dieser Teil 2-1 behandelt die Prüfart A F/R und gilt nur für Starkstromkabel mit Leiternennquerschnitten grösser 35 mm[2], die mit Abstand auf der Vorder- und der Rückseite der Prüfleiter installiert sind, um ein nominales Volumen an nicht-metallenem Werkstoff von 7 l/m der Probe zu erreichen. Die Dauer der Flammenbeaufschlagung beträgt 40 min. Dieses Verfahren der Aufleiterung ist für spezielle Kabelbauarten gedacht, die, sofern in der Kabelspezifikation gefordert, in besonderen Installationen verwendet werden. Die Prüfart A F/R ist nicht für die allgemeine Verwendung vorgesehen. Eine Empfehlung für Leistungsanforderungen ist in Anhang B angegeben.

DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Withdrawn

Standards Relationship
DIN EN 50266-2-1 : 2001 Identical
EN 50266-2-1 : 2001 COR 2002 Identical
DIN EN 50266-2-1 : 2001 Corresponds

IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
DIN EN 60811-1-3 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
EN 50266-1:2001 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Part 1: Apparatus
VDE 0473-811-1-3 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION; SECTION 3: METHODS FOR DETERMINING THE DENSITY, WATER ABSORPTION TESTS, SHRINKAGE TEST
VDE 0482-266-1 : 2001 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - PART 1: APPARATUS
EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
DIN EN 60695-4 : 2013 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
VDE 0471-4 : 2013 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)
IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
DIN EN 50266-1 : 2001 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - PART 1: APPARATUS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more