• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM C 1309 : 1997

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

10-12-1997

CONTAINED IN VOL. 12.01, 2015 Specifies one of several practices developed to assist operators of nuclear facilities with meeting the metal detection performance requirements set by regulatory authorities.

1.1 This practice is one of several (see Appendix X1) developed to assist operators of nuclear facilities with meeting the metal detection performance requirements set by regulatory authorities.

1.2 This practice consists of four procedures useful for evaluating the in-plant performance of walk-through metal detectors (see Fig. 1).

1.2.1 Two of the procedures provide data for evaluating probability of detection. These procedures use binomial data (alarm/not alarm).

1.2.1.1 The detection sensitivity test (DST) is the initial procedure in the detection probability evaluation series. It is used to establish the probability of detection immediately after the detector has been adjusted to its operational sensitivity setting.

1.2.1.2 The detection sensitivity verification test (DSVT) procedure periodically provides data for evaluation of continuing detection performance.

1.2.2 The third procedure is a "functional test." It is used routinely to verify that a metal detector is operating and responds with the correct audio and visual signals when subjected to a condition that should cause an alarm.

1.2.3 The fourth procedure is used to verify that alarms generated during detection sensitivity testing were likely the result of the detection of metal and not caused by outside interferences or the perturbation of the detection field by the tester's body mass.

1.2.3.1 This procedure also can be used to establish a probability of occurrence for false alarms, for example, 20 test passes by a clean-tester resulting in no alarms indicates a false alarm probability of less than 0.15 at 95% confidence. This procedure is optional unless required by the regulatory authority.

1.3 This practice does not set test object specifications. The specifications should be issued by the regulatory authority.

1.4 This practice is intended neither to set performance levels nor to limit or constrain technologies.

1.5 This practice does not address safety or operational issues associated with the use of walk-through metal detectors.

Committee
C 26
DocumentType
Standard Practice
Pages
14
ProductNote
Reconfirmed 1997
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM C 1269 : 1997 : R2012 Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors
ASTM C 1270 : 1997 : R2012 Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through<brk> Metal Detectors

ASTM C 1269 : 1997 Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors
ASTM C 1270 : 1997 Standard Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal Detectors
ASTM C 1238 : 1997 Standard Guide for Installation of Walk-Through Metal Detectors

View more information
£70.87
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.