• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM D 3752 : 1998 : R2002 : EDT 1

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Test Method for Strength Imparted by Asbestos to a Cementitious Matrix

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

10-08-1998

1.1 This test method covers the measurement, on a laboratory scale, of the contribution of asbestos fibers to the strength of asbestos-cement products. The results obtained are used in the primary assessment of different fiber grades prior to their application on a larger scale.

1.2 This test method covers the determination of the modulus of rupture (MR), adjusted to a dry density of 1.60 Mg/m3 (MR A), of asbestos-cement test specimens that contain the asbestos fiber to be evaluated at a concentration of 10 mass %, whereby the degree of fiberization of that fiber is specified in terms of specific surface area as determined by Test Method D 2752. The relative reinforcing value of the fiber under test is established by comparison with MRA values obtained with a fiber of known characteristics at a fiber concentration of 10 % and a dry density of 1.60 Mg/m3 (1.60 g/cm3). Note 1The adjusted modulus of rupture (MRA) at any intermediate fiber concentration may be interpolated from results suitably determined over a limited spanning range of fiber concentrations. For example, the MRA at 10 % fiber concentration may be graphically determined from data at 3 and 17 %.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysotile asbestos, refer to "Safe Use of Chrysotile: A Manual on Preventive and Control Measures."

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
C 17
DocumentType
Test Method
Pages
7
ProductNote
Reconfirmed EDT 1
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM C 1119/C1119M : 1990 : R2015 Standard Test Method for Vacuum Drainage of Asbestos-Cement Mixes (Withdrawn 2021)
ASTM D 2590/D2590M : 1998 : R2019 Standard Test Method for Sampling Chrysotile Asbestos (Withdrawn 2022)
ASTM D 3880/D3880M : 1990 : R2017 Standard Test Method for Asbestos Strength Units (Withdrawn 2022)

View more information
£62.61
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.