We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
  • ASTM E 2964 : 2019

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist.
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You need to be logged in to add this standard to your Watchlist.
    Please log in now or create an account to add.
    You already added this Product in the Watchlist.

    Standard Test Method for Measurement of the Normalized Insertion Loss of Doors

    Available format(s):  Hardcopy, PDF

    Superseded date:  24-09-2021

    Language(s):  English

    Published date:  01-05-2019

    Publisher:  American Society for Testing and Materials

    Add to Watchlist

    Add To Cart

    Abstract - (Show below) - (Hide below)

    The sound insulation properties of a door are measured in a laboratory as the sound transmission loss in accordance with Test MethodE90.

    Scope - (Show below) - (Hide below)

    1.1The sound insulation properties of a door are measured in a laboratory as the sound transmission loss in accordance with Test Method E90. Using those data single number rating sound transmission class (STC) is assigned. In the field, the rooms on one or both sides of a partition containing a door are often either too small or too large and absorptive to allow the apparent transmission loss (ATL) of the partition-door assembly to be measured. Even if that is not the case, the result measured is the composite ATL of the partition including the door, and not that of the door itself. Test Method E336 actually states that it is impossible to measure the ATL of a portion of a partition such as a door according to the procedures of that standard. This test method provides a method of evaluating doors in such cases using a normalized insertion loss with a resulting single number rating door transmission class, DTC. This method is intended primarily for hinged personnel doors with latching mechanisms and is limited to door openings of area less than 6 m2. The flanking effects of surrounding structure are reduced compared to Test Method E336 but not completely eliminated. In a laboratory environment, the DTC is close to or equal to the STC of the door, but in the field results less than the laboratory STC should be expected.

    1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

    1.4This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

    General Product Information - (Show below) - (Hide below)

    Committee E 33
    Document Type Test Method
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    ASTM E 966 : 2018 : REV A Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements
    ASTM E 1374 : 2018 : EDT 1 Standard Guide for Office Acoustics and Applicable ASTM Standards
    ASTM E 3091 : 2017 Standard Specification for Systems to Measure Sound Levels
    ASTM E 336 : 2019 Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
    ASTM E 336 : 2020 Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM E 1414 : 2000 : REV A Standard Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum
    ASTM C 634 : 2013 : EDT 1 Standard Terminology Relating to Building and Environmental Acoustics
    ASTM E 1007 : 2019 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
    ASTM C 634 : 2013 : R2021 Standard Terminology Relating to Building and Environmental Acoustics
    ASTM E 1007 : 2011 : EDT 1 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
    ASTM E 1007 : 2013 : REV A Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
    ASTM E 1414 : 2006 Standard Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum
    ASTM E 1007 : 1997 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
    ASTM E 1007 : 2021 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
    ASTM E 1007 : 2013 : REV B Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
    ASTM E 1007 : 2014 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
    ASTM E 1007 : 2004 : EDT 1 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
    ASTM E 1007 : 2016 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective