BS 1695-2:1990

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Urological catheters Specification for sterile, single-use urethral catheters of the Tiemann, whistle tip, 3-way and haematuria types

Available format(s)

Hardcopy , PDF

Superseded date

15-07-1997

Language(s)

English

Published date

30-09-1990

Committees responsible
Foreword
Specification
1 Scope
2 Definitions
3 Finish
4 Freedom from particulate contamination
5 Gauge size
6 Tip
7 Drainage eyes
8 Balloon
9 Shaft
10 Funnels
11 Marking of catheters
12 Packaging
13 Marking of packages
14 Biological hazard
Appendices
A Guidance on design and materials
B Summary of schedule of performance tests
C Method for determining gauge size of catheter
D Method for determining the security of the tip to
    the shaft of the catheter
E Method for determining occlusion of drainage eyes
    and leakage from balloon
F Method for determining inflation lumen leakage and/
    or valve function and/or balloon deflation
G Method for determining flow rate of drainage and
    irrigation lumen
H Method for determining the resistance of the
    drainage lumen of haematuria catheters to collapse
    or too occlusion under reduced pressure
J Method for determining the integrity of the junction
    between the drainage funnel and the shaft of the
    catheter
K Method for determining the security of fit of the
    drainage funnel
L Method for determining the integrity of the junction
    between the inflation funnel and the shaft of the
    catheter
M Method for determining the security of fit of the
    irrigation funnel
N Symbol for 'Do not re-use'
P Method for determining the toxicity of catheters to
    cells in culture
Tables
1 Range of catheter sizes
2 Balloon test volume percentage recovery
3 Balloon capacities
4 Tip lengths
5 Shaft and funnel dimensions
6 Average flow rates
7 Requirements for load test
8 Balloon test capacities
9 Conditions for preparing extracts for cytotoxicity
    testing
Figures
1 Typical Tiemann catheter without balloon
2 Typical Tiemann catheter with balloon
3 Typical whistle tip catheter without balloon
4 Typical whistle tip catheter with balloon
5 Typical 3-way catheter with balloon
6 Typical haematuria catheter with balloon
7 Typical cross-sectional configurations of catheter
    shaft and designation of lumen dimensions
8 Apparatus and general arrangement for testing
    security of catheter tip
9 Apparatus for flow rate test
10 Apparatus and general arrangement for test of
    resistance of the drainage lumen of haematuria
    catheters to collapse or occlusion under reduced
    pressure
11 Test connector and general arrangement for testing
    security of fit of the drainage funnel
12 General arrangement for testing the integrity of the
    junction between the inflation and irrigation
    funnels and the shaft of the catheter
13 ISO symbol 'Do not re-use', Registration No. ISO
    7000/1051

Dimensional and performance requirements for Tiemann and whistle tip urethral catheters with and without balloons, and for 3-way and haematuria urethral catheters with balloons.

Committee
CH/84
DocumentType
Standard
Pages
38
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

BS 1695-1:1990 Urological catheters Specification for sterile, single-use urethral catheters of the Nélaton and Foley types

BS 5736-6:1983 Evaluation of medical devices for biological hazards Methods of test for sensitization; assessment of the potential of medical devices to produce delayed contact dermatitis
BS 5736-10:1988 Evaluation of medical devices for biological hazards Method of test for toxicity to cells in culture of extracts from medical devices
ISO 3461:1976 Graphic symbols — General principles for presentation
BS 5736-4:1981 Evaluation of medical devices for biological hazards Method of test for intracutaneous reactivity of extracts from medical devices
BS 5404-2:1977 Specification for plastics laboratory ware Graduated measuring cylinders
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
BS 3930-1(1987) : AMD 8072 CONICAL FITTINGS WITH A 6% (LUER) TAPER FOR SYRINGES, NEEDLES AND OTHER MEDICAL EQUIPMENT - SPECIFICATION FOR GENERAL REQUIREMENTS

View more information
£232.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.