Specification for transformers for use in ships

Available format(s)

Hardcopy , PDF

Withdrawn date

02-08-2013

Language(s)

English

Published date

31-07-1961

Cooperating organizations
Foreword
Section One: General
101. Scope
102. Definitions
103. Additional definitions
Section Two: Type of cooling and classification
201. Types of cooling
Section Three: Rating
301. Rated kVA
302. Rated voltage and current
303. Rated frequency
304. Phase factors
305. Rating of additional windings
306. Preferred kVA ratings
307. Regulation
Section Four: Service conditions
401. General
Section Five: Constructional requirements
501. General
Section Six: Tappings
601. General
602. Principal tapping
603. Output at any tapping
Section Seven: Insulating materials
701. General
702. Solids
703. Liquids
Section Eight: Insulation levels
801. General
Section Nine: Temperature rise limits
901. General
Section Ten: Performance under external short-circuit
conditions
1001. General
1002. Series current-limiting reactors
Section Eleven: Assignment of designating letters to
windings and of numbers to winding ends and tappings
1101. Designating letters
1102. Subscript numbers for winding ends and tappings
Section Twelve: Marking of terminals
1201. Terminal and sub-terminal markings for
       transformers
1202. Terminal markings for series current-limiting
       reactors
Section Thirteen: Position of terminals
1301. General
Section Fourteen: Vector diagrams and symbols
1401. Vector diagrams and symbols
Section Fifteen: Terminal marking plates and rating
plates
1501. Terminal marking plates
1502. Rating plates for transformers
1503. Rating plates for series current-limiting reators
Section Sixteen: Fittings
1601. Provision of fittings
Section Seventeen: Performance tolerances
1701. Efficiency
1702. Performance and tolerances
Section Eighteen: Tests
1801. Conditions for tests
1802. Tests of transformers
1803 Test certificates
1804. Measurement of winding resistance
1805. Ratio measurement, check of polarity and phase
       relationship
1806. Measurement of impedance voltage
1807. Measurement of load loss
1808. Measurement of no-load losses and no-load current
1809. Measurement of insulation resistance
1810. Induced overvoltage withstand test
1811. Separate-source voltage withstand test
1812. Test of temperature rise
1813. Series current-limiting reactors
Appendices
A. Information required with enquiry and order
B. Additional fittings for oil-immersed type
    transformers
C. Three-phase vector diagrams
D. Connection diagrams
E. Method of declaring efficiency
F. Calculation of inherent regulation
G. Supplementary high-voltage tests

Single-phase and polyphase, double wound power transformers and reactors having windings insulated with Class A, B, H or C materials, 1 kVA to 1000 kVA and rated line to line voltage up to 3300 volts. Dry and oil-immersed transformers. For service in ships sailing in temperate or tropical waters. Limits of temperature rise, regulation, performance requirements, ratings, terminal markings. Cooling methods classified, position of external terminals, list of external fittings and their positions. Routine tests, temperature rise test. Supplementary high-voltage tests, methods of declaring efficiency, calculation of inherent regulation, connection diagrams, vector diagrams, information with enquiry and order, additional fittings for oil-immersed transformers. Illustrated.

Committee
PEL/14
DevelopmentNote
Inactive for the new design. (08/2008)
DocumentType
Standard
Pages
54
PublisherName
British Standards Institution
Status
Withdrawn

BS MA 52:1974 Specification for ships\' deck machinery - accommodation ladder winches
BS MA 34:1973 Specification for ships\' deck machinery - capstans
DEFSTAN 02-718/1(2002) : 2002 REQUIREMENTS FOR SEWAGE PLANT AND ANCILLARY EQUIPMENT IN HM SURFACE SHIPS AND SUBMARINES
DEFSTAN 02-122/1(2002) : INTERIM REQUIREMENTS FOR CATERING EQUIPMENT
BS MA 35:1975 Specification for ships\' deck machinery - windlasses
BS MA 36:1974 Specification for ships\' deck machinery - topping winches
BS MA 31:1973 Specification for ships\' deck machinery - cargo winches
DEFSTAN 02-535/2(2003) : 2003 REQUIREMENTS FOR TRANSFORMERS FOR POWER SERVICES
BS MA 53:1975 Specification for ships\' deck machinery - towing winches for deep sea use
BS MA 55:1975 Specification for ships\' deck machinery - lifeboat winches
BS MA 79:1978 Specification for jib cranes: ship mounted type
BS MA 33:1973 Specification for ships\' deck machinery - warping winches

BS CP1009(1959) : LATEST MAINTENANCE OF INSULATING OIL (WITH SPECIAL REFERENCE TO TRANSFORMERS AND SWITCHGEAR)
BS 171:1970 Specification for power transformers
BS 2562:1979 Specification for cable boxes for transformers and reactors

View more information
£276.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.