BS EN 60146-1-3:1993

Current

Current

The latest, up-to-date edition.

Semiconductor convertors. General requirements and line commutated convertors Transformers and reactors

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-05-1993

Cooperating organizations
National foreword
Foreword
1 Scope
2 Normative references
3 Rated values for convertor transformers
3.1 Rated current values
3.2 Temperature limits of cooling media
4 Losses and voltage drops in transformers and
     reactors
4.1 Losses in the transformer windings
4.2 Losses in interphase transformers, current
     balancing reactors, series-smoothing reactors,
     transductors and other current regulating
     accessories
4.3 Voltage drops in transformers and reactors
5 Tests for convertor transformers
5.1 Measurement of commutating reactance and
     determination of inductive voltage drop (type test)
5.2 Short-circuit test (type test and routine test)
5.3 Temperature rise test (type test)
Annex
A (normative) Corrections to be applied when cooling
      medium temperature is higher than standard
ZA (normative) Other international publications
     quoted in this standard with the references of the
     relevant European publications
Tables
1 Temperature rise limits
2 Connections and calculation factors
National annex NA (informative) Committees responsible
National annex NB (informative) Cross-references

Relates to the characteristics wherein convertor transformers differ from ordinary power transformers. Includes the following sections: rated values for convertor transformers; losses and voltage drops in transformers and reactors; tests for convertor transformers.

This Part 1-3 of the International Standard relates, in general, to those characteristics wherein convertor transformers differ from ordinary power transformers. In all other respects, the rules specified in IEC 76 shall apply to convertor transformers also, as far as they are not in contradiction with this standard.

It should be borne in mind that a rectifier transformer operates with non-sinusoidal current waveshape. In single-way connection, the current in each cell winding contains a d.c. component which calls for special attention in design and testing. In some cases, a special design is necessary when external short-circuits and cell failures would cause abnormal stress.

For certain types of transformers, the waveshape of the normal operating voltage is non-sinusoidal. The core loss of such equipment is to be determined by applying a sinusoidal voltage having the same half-cycle arithmetic mean value and the same fundamental frequency as the voltage applied in service.

Committee
PEL/22
DevelopmentNote
Also numbered as IEC 60146-1-3 Together with BS EN 60146-1.1, it supersedes BS 4417(1969) Supersedes 92/17370 DC (08/2003)
DocumentType
Standard
Pages
16
PublisherName
British Standards Institution
Status
Current
SupersededBy
Supersedes

Standards Relationship
SN EN 60146-1-3 : 1993 Identical
EN 60146-1-3:1993 Identical
UNE-EN 60146-1-3:1996 Identical
NF EN 60146-1-3 : 1993 Identical
I.S. EN 60146-1-3:1993 Identical
DIN EN 60146-1-3 : 1994 Identical

BS 171:1970 Specification for power transformers
BS EN 60146-1-1:2010 Semiconductor converters. General requirements and line commutated converters Specification of basic requirements

View more information
£142.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.