BS EN 60601-2-43:2010+A2:2020

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures

Available format(s)

Hardcopy , PDF

Superseded date

25-01-2023

Language(s)

English

Published date

08-04-2020

Clause1 of the general standard1) applies, except as follows: 201.1.1 *Scope Replacement: This International Standard applies to the basic safety and essential performance of both fixed and mobile x-ray equipment declared by the manufacturer to be suitable for radioscopically guided interventional procedures, hereafter referred to as interventional X-ray equipment. Its scope excludes, in particular: equipment for radiotherapy; equipment for computed tomography; accessories intended to be introduced into the patient; mammographic X-ray equipment; dental X-ray equipment. NOTE1 Examples of radioscopically guided interventional procedures, for which the use of interventional X-ray equipment complying with this standard is recommended, are given in AnnexAA. NOTE2 Specific requirements for magnetic navigation devices, and for the use of interventional X-ray equipment in an operating room environment were not considered in this particular standard; therefore no specific requirements have been developed for these devices or uses. In any case, such devices or uses remain under the general clause requirements. NOTE3 interventional X-ray equipment, when used for cone-beam CT mode, is covered by this standard and not by IEC60601‑2‑44 [2]2. No additional requirements for operation in cone-beam CT mode were identified for this standard (see also Note4 in 203.6.4.5). interventional X-ray equipment declared by the manufacturer to be suitable for radioscopically guided interventional procedures, which does not include a patient support as part of the system, is exempt from the patient support provisions of this standard. If a clause or subclause is specifically intended to be applicable to interventional X-ray equipment only, or to me systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to interventional X-ray equipment and to me systems, as relevant. NOTE4 See also 4.2 of the general standard. The subclauses of this standard supersede IEC60601‑2‑54 subclauses. IEC60601‑2‑54 applies only with regards to the cited subclauses; non-cited subclauses of IEC60601‑2‑54 do not apply. 201.1.2 Object Replacement: The object of this particular standard is: to establish particular basic safety and essential performance requirements for the design and manufacture of X-ray equipment for radioscopically guided interventional procedures, as defined in 201.3.203. to specify information which is to be provided with such interventional X-ray equipment for the assistance of the responsible organization and operator in managing the radiation risk and equipment failure risk arising from these procedures which could affect patients or staff. 201.1.3 Collateral standards Addition: This particular standard refers to those applicable collateral standards that are listed in Clause2 of the general standard and Clause201.2 of this particular standard. IEC60601‑1‑2 and IEC60601‑1‑3 apply as modified in Clause202 and Clause203 respectively. IEC60601‑1‑8 3 ), IEC60601‑1‑9 4 ), IEC60601‑1‑10 5 ), IEC60601‑1‑11 6 ) and IEC60601‑1‑12 7) do not apply. All other published collateral standards in the IEC60601‑1 series apply as published. 201.1.4 Particular standards Replacement: In the IEC60601 series, particular standards may modify, replace or delete requirements contained in the general standard and collateral standards as appropriate for the particular me equipment under consideration, and may add other basic safety and essential performance requirements. A requirement of a particular standard takes priority over the general standard. For brevity, IEC60601‑1 is referred to in this particular standard as the general standard. Collateral standards are referred to by their document number. The numbering of clauses and subclauses of this particular standard corresponds to that of the general standard with the prefix “201?? (e.g. 201.1 in this standard addresses the content of Clause1 of the general standard) or applicable collateral standard with the prefix “20x?? where x is the final digit(s) of the collateral standard document number (e.g. 202.4 in this particular standard addresses the content of Clause4 of the IEC60601‑1‑2 collateral standard, 203.4 in this particular standard addresses the content of Clause4 of the IEC60601‑1‑3 collateral standard, etc.). The changes to the text of the general standard are specified by the use of the following words: \'Replacement\' means that the clause or subclause of the general standard or applicable collateral standard is replaced completely by the text of this particular standard. \'Addition\' means that the text of this particular standard is additional to the requirements of the general standard or applicable collateral standard. \'Amendment\' means that the clause or subclause of the general standard or applicable collateral standard is amended as indicated by the text of this particular standard. Subclauses, figures or tables which are additional to those of the general standard are numbered starting from 201.101. However, due to the fact that definitions in the general standard are numbered 3.1 through 3.139, additional definitions in this standard are numbered beginning from 201.3.201. Additional annexes are lettered AA, BB, etc., and additional items aa), bb), etc. Subclauses, figures or tables which are additional to those of a collateral standard are numbered starting from 20x, where “x?? is the number of the collateral standard, e.g. 202 for IEC60601‑1‑2, 203 for IEC60601‑1‑3, etc. The term \'this standard\' is used to make reference to the general standard, any applicable collateral standards and this particular standard taken together. Where there is no corresponding clause or subclause in this particular standard, the clause or subclause of the general standard or applicable collateral standard, although possibly not relevant, applies without modification; where it is intended that any part of the general standard or applicable collateral standard, although possibly relevant, is not to be applied, a statement to that effect is given in this particular standard.

Committee
CH/62/2
DocumentType
Standard
Pages
74
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 60601-2-43:2010/AMD2:2019 Identical

View more information
£314.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.