• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CSA C61869-11:20

Current

Current

The latest, up-to-date edition.

Instrument transformers — Part 11: Additional requirements for low-power passive voltage transformers (Adopted IEC 61869-11:2017, first edition, 2017-12, with Canadian deviations) | Transformateurs de mesure — Partie 11 : Exigences supplémentaires pour les transformateurs de tension passifs de faible puissance (norme IEC 61869-11:2017 adoptée, (première édition, 2017-12, avec exigences propres au Canada)

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

01-01-2020

CSA Preface This is the first edition of CSA C61869-11, Instrument transformers — Part 11: Additional requirements for low-power passive voltage transformers , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61869-11 (first edition, 2017-12). It replaces relevant parts of CAN/CSA-C60044-7:07 (adopted IEC 60044-7:1999), Instrument transformers — Part 7: Electronic voltage transformers, and of CAN/CSA-C60044-8:07 (adopted IEC 60044-8:2002), Instrument transformers — Part 8: Electronic current transformers. It is part of the CSA C61869 series of Standards on instrument transformers, which consists of adoptions with Canadian deviations of the IEC 61869 series of Standards. This Standard is intended to be used in conjunction with CAN/CSA-C61869-1:14, Instrument transformers — Part 1: General requirements (adopted IEC 61869-1:2007, with Canadian deviations); and CSA C61869-6:20, Instrument transformers — Part 6: Additional general requirements for low-power instrument transformers (adopted IEC 61869-6:2016, with Canadian deviations). Requirements common to all instrument transformer types are grouped in CAN/CSA-C61869-1. Requirements specific to conventional instrument transformer types are grouped in CAN/CSA-C61869-2, CAN/CSA-C61869-3, CAN/CSA-C61869-4, and CAN/CSA-C61869-5. Those CSA Group Standards present many inherited Canadian deviations justified by the specific conditions, practices, and regulations in Canada. Requirements common to low-power instrument transformers (LPIT) used for ac applications having rated frequencies from 15 Hz to 100 Hz covering MV, HV, and EHV or used for dc applications are grouped in CSA C61869-6. The remaining Standards in the series state requirements for specific types of instrument transformers. Canada has actively participated in the development of IEC 61869-11, in order to enforce specific Canadian conditions. It should be noted that Parts 6 to 13 of the IEC 61869 series specify the requirements for ac LPIT as well as the interfaces necessary to implement the LPIT into an integrated system for protection and measurement. Such a system uses a universal digital transmission protocol compatible with IEC 61850, and has a digital output. In order to ensure full interoperability, Canadian deviations in CSA C61869-11 are minimal. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 61869 is a product standard and covers only additional requirements for low-power passive voltage transformers (passive LPVT). The product standard for low-power passive voltage transformers is composed of IEC 61869-1, along with IEC 61869-6 and this document with specific requirements. This document is applicable to newly manufactured low-power passive voltage transformers with analogue output having rated frequencies from 15 Hz to 100 Hz for use with electrical measuring instruments or electrical protective devices. This document covers low-power passive voltage transformers used for measurement or protection and low-power passive voltage transformers used for both measurement and protection. Low-power passive voltage transformers have analogue output only (for digital output or for technology using any kind of active electronic components refer to future IEC 61869-72). Such low-power passive voltage transformers can include the secondary signal cable (transmitting cable). The secondary voltage of the low-power passive voltage transformer is proportional to the primary voltage. Derivative output signals are not within the scope of this document. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la première édition de CSA C61869-11, Transformateurs de mesure — Partie 11 : Exigences supplémentaires pour les transformateurs de tension passifs de faible puissance . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61869-11 (première édition, 2017-12), qui porte le même titre. Il remplace les parties pertinentes de CAN/CSA-C60044-7:07 (norme IEC 60044-7:1999 adoptée), Transformateurs de mesure — Partie 7 : Transformateurs de tension électroniques, et de CAN/CSA-C60044-8:07 (norme IEC 60044-8:2002 adoptée), Instrument transformers — Part 8: Electronic current transformers. Il fait partie de la série de normes CSA C61869 sur les transformateurs de mesure, laquelle est constituée de l’adoption, avec exigences propres au Canada, des normes de la série IEC 61869. Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C61869-1:14, Transformateurs de mesure — Partie 1 : Exigences générales (norme IEC 61869-1:2007 adoptée, avec exigences propres au Canada); et CSA C61869-6, Transformateurs de mesure — Partie 6 : Exigences générales supplémentaires concernant les transformateurs de mesure de faible puissance (norme IEC 61869-6:2016 adoptée, avec exigences propres au Canada). Les exigences qui s’appliquent à tous les types de transformateurs de mesure sont regroupées dans CAN/CSA-C61869-1. Les exigences propres aux types de transformateur de mesure conventionnels sont regroupées dans CAN/CSA-C61869-2, CAN/CSA-C61869-3, CAN/CSA-C61869-4 et CAN/CSA-C61869-5. Ces normes de Groupe CSA présentent de nombreuses exigences propres au Canada hérités justifiés par les conditions, pratiques et règlements particuliers du Canada. Les exigences qui s’appliquent aux transformateurs de mesure de faible puissance (LPIT) utilisés pour les applications en courant alternatif présentant des fréquences assignées comprises entre 15 Hz et 100 Hz couvrant les applications moyenne tension (MT), haute tension (HT) et très haute tension (THT) ou utilisés pour les applications en courant continu, sont regroupées dans CSA C61869-6. Les autres normes de la série énoncent des exigences particulières aux types spécifiques de transformateurs de mesure. Le Canada a participé activement à la rédaction d’IEC 61869-11 pour que soient prises en compte les conditions propres au Canada. Il convient de noter que les parties 6 à 13 de la série IEC 61869 spécifient les exigences visant le LPIT à courant alternatif ainsi que les interfaces nécessaires pour mettre en oeuvre le LPIT dans un système intégré utilisés pour la protection et la mesure. Un tel système utilise un protocole de transmission numérique universel compatible avec IEC 61850, et a une sortie numérique. Afin que soit assurée la pleine interopérabilité, les exigences propres au Canada dans CSA C61869-11 sont minimes. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application La présente partie de l\'IEC 61869 est une norme de produit qui traite uniquement des exigences supplémentaires concernant les transformateurs de tension passifs de faible puissance (LPVT passif). La norme de produit relative aux transformateurs de tension passifs de faible puissance comprend l\'IEC 61869-1, ainsi que l\'IEC 61869-6 et le présent document portant sur les exigences spécifiques. Le présent document s\'applique aux transformateurs de tension passifs de faible puissance à sortie analogique et destinés à être utilisés avec des appareils de mesure électriques ou des dispositifs électriques de protection présentant une fréquence assignée comprise entre 15 Hz et 100 Hz. Le présent document traite des transformateurs de tension passifs de faible puissance utilisés pour la mesure ou la protection, ainsi que des transformateurs de tension passifs de faible puissance utilisés à la fois pour la mesure et la protection. Les transformateurs de tension passifs de faible puissance ont une sortie exclusivement analogique (se reporter à la future IEC 61869-72 pour une sortie numérique ou pour une technologie basée sur des composants électroniques actifs). Ces transformateurs de tension passifs de faible puissance peuvent comporter le câble de transmission du signal secondaire. La tension secondaire du transformateur de tension passif de faible puissance est proportionnelle à la tension primaire. Les signaux de sortie dérivés n\'entrent pas dans le domaine d\'application de la présente partie de l\'IEC 61869.

CSA Preface This is the first edition of CSA C61869-11, Instrument transformers — Part 11: Additional requirements for low-power passive voltage transformers , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61869-11 (first edition, 2017-12). It replaces relevant parts of CAN/CSA-C60044-7:07 (adopted IEC 60044-7:1999), Instrument transformers — Part 7: Electronic voltage transformers, and of CAN/CSA-C60044-8:07 (adopted IEC 60044-8:2002), Instrument transformers — Part 8: Electronic current transformers. It is part of the CSA C61869 series of Standards on instrument transformers, which consists of adoptions with Canadian deviations of the IEC 61869 series of Standards. This Standard is intended to be used in conjunction with CAN/CSA-C61869-1:14, Instrument transformers — Part 1: General requirements (adopted IEC 61869-1:2007, with Canadian deviations); and CSA C61869-6:20, Instrument transformers — Part 6: Additional general requirements for low-power instrument transformers (adopted IEC 61869-6:2016, with Canadian deviations). Requirements common to all instrument transformer types are grouped in CAN/CSA-C61869-1. Requirements specific to conventional instrument transformer types are grouped in CAN/CSA-C61869-2, CAN/CSA-C61869-3, CAN/CSA-C61869-4, and CAN/CSA-C61869-5. Those CSA Group Standards present many inherited Canadian deviations justified by the specific conditions, practices, and regulations in Canada. Requirements common to low-power instrument transformers (LPIT) used for ac applications having rated frequencies from 15 Hz to 100 Hz covering MV, HV, and EHV or used for dc applications are grouped in CSA C61869-6. The remaining Standards in the series state requirements for specific types of instrument transformers. Canada has actively participated in the development of IEC 61869-11, in order to enforce specific Canadian conditions. It should be noted that Parts 6 to 13 of the IEC 61869 series specify the requirements for ac LPIT as well as the interfaces necessary to implement the LPIT into an integrated system for protection and measurement. Such a system uses a universal digital transmission protocol compatible with IEC 61850, and has a digital output. In order to ensure full interoperability, Canadian deviations in CSA C61869-11 are minimal. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of IEC 61869 is a product standard and covers only additional requirements for low-power passive voltage transformers (passive LPVT). The product standard for low-power passive voltage transformers is composed of IEC 61869-1, along with IEC 61869-6 and this document with specific requirements. This document is applicable to newly manufactured low-power passive voltage transformers with analogue output having rated frequencies from 15 Hz to 100 Hz for use with electrical measuring instruments or electrical protective devices. This document covers low-power passive voltage transformers used for measurement or protection and low-power passive voltage transformers used for both measurement and protection. Low-power passive voltage transformers have analogue output only (for digital output or for technology using any kind of active electronic components refer to future IEC 61869-72). Such low-power passive voltage transformers can include the secondary signal cable (transmitting cable). The secondary voltage of the low-power passive voltage transformer is proportional to the primary voltage. Derivative output signals are not within the scope of this document. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la première édition de CSA C61869-11, Transformateurs de mesure — Partie 11 : Exigences supplémentaires pour les transformateurs de tension passifs de faible puissance . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61869-11 (première édition, 2017-12), qui porte le même titre. Il remplace les parties pertinentes de CAN/CSA-C60044-7:07 (norme IEC 60044-7:1999 adoptée), Transformateurs de mesure — Partie 7 : Transformateurs de tension électroniques, et de CAN/CSA-C60044-8:07 (norme IEC 60044-8:2002 adoptée), Instrument transformers — Part 8: Electronic current transformers. Il fait partie de la série de normes CSA C61869 sur les transformateurs de mesure, laquelle est constituée de l’adoption, avec exigences propres au Canada, des normes de la série IEC 61869. Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C61869-1:14, Transformateurs de mesure — Partie 1 : Exigences générales (norme IEC 61869-1:2007 adoptée, avec exigences propres au Canada); et CSA C61869-6, Transformateurs de mesure — Partie 6 : Exigences générales supplémentaires concernant les transformateurs de mesure de faible puissance (norme IEC 61869-6:2016 adoptée, avec exigences propres au Canada). Les exigences qui s’appliquent à tous les types de transformateurs de mesure sont regroupées dans CAN/CSA-C61869-1. Les exigences propres aux types de transformateur de mesure conventionnels sont regroupées dans CAN/CSA-C61869-2, CAN/CSA-C61869-3, CAN/CSA-C61869-4 et CAN/CSA-C61869-5. Ces normes de Groupe CSA présentent de nombreuses exigences propres au Canada hérités justifiés par les conditions, pratiques et règlements particuliers du Canada. Les exigences qui s’appliquent aux transformateurs de mesure de faible puissance (LPIT) utilisés pour les applications en courant alternatif présentant des fréquences assignées comprises entre 15 Hz et 100 Hz couvrant les applications moyenne tension (MT), haute tension (HT) et très haute tension (THT) ou utilisés pour les applications en courant continu, sont regroupées dans CSA C61869-6. Les autres normes de la série énoncent des exigences particulières aux types spécifiques de transformateurs de mesure. Le Canada a participé activement à la rédaction d’IEC 61869-11 pour que soient prises en compte les conditions propres au Canada. Il convient de noter que les parties 6 à 13 de la série IEC 61869 spécifient les exigences visant le LPIT à courant alternatif ainsi que les interfaces nécessaires pour mettre en oeuvre le LPIT dans un système intégré utilisés pour la protection et la mesure. Un tel système utilise un protocole de transmission numérique universel compatible avec IEC 61850, et a une sortie numérique. Afin que soit assurée la pleine interopérabilité, les exigences propres au Canada dans CSA C61869-11 sont minimes. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application La présente partie de l\'IEC 61869 est une norme de produit qui traite uniquement des exigences supplémentaires concernant les transformateurs de tension passifs de faible puissance (LPVT passif). La norme de produit relative aux transformateurs de tension passifs de faible puissance comprend l\'IEC 61869-1, ainsi que l\'IEC 61869-6 et le présent document portant sur les exigences spécifiques. Le présent document s\'applique aux transformateurs de tension passifs de faible puissance à sortie analogique et destinés à être utilisés avec des appareils de mesure électriques ou des dispositifs électriques de protection présentant une fréquence assignée comprise entre 15 Hz et 100 Hz. Le présent document traite des transformateurs de tension passifs de faible puissance utilisés pour la mesure ou la protection, ainsi que des transformateurs de tension passifs de faible puissance utilisés à la fois pour la mesure et la protection. Les transformateurs de tension passifs de faible puissance ont une sortie exclusivement analogique (se reporter à la future IEC 61869-72 pour une sortie numérique ou pour une technologie basée sur des composants électroniques actifs). Ces transformateurs de tension passifs de faible puissance peuvent comporter le câble de transmission du signal secondaire. La tension secondaire du transformateur de tension passif de faible puissance est proportionnelle à la tension primaire. Les signaux de sortie dérivés n\'entrent pas dans le domaine d\'application de la présente partie de l\'IEC 61869.

DocumentType
Standard
ISBN
978-1-4883-2761-2
Pages
93
ProductNote
THIS STANDARD IS ALSO REFERS TO CSA C61869-6:20, IEC 61869-7
PublisherName
Canadian Standards Association
Status
Current
Supersedes

View more information
£213.47
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.