• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CSA ISO 5367:19

Current

Current

The latest, up-to-date edition.

Anaesthetic and respiratory equipment — Breathing sets and connectors (Adopted ISO 5367:2014, fifth edition, 2014-10-15)

Available format(s)

Hardcopy , PDF

Language(s)

English, French

Published date

01-01-2019

CSA Preface This is the second edition of CSA ISO 5367-19, Anaesthetic and respiratory equipment — Breathing sets and connectors, which is an adoption without modification of the identically titled ISO (International Organization for Standardization) Standard 5367 (fifth edition, 2014-10-15). It supersedes the previous edition published in 2014 as CAN/CSA-ISO 5367, Breathing tubes intended for use with anaesthetic apparatus and ventilators (adopted ISO 5367:2000). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope *This International Standard specifies basic requirements for breathing sets and breathing tubes intended to be used with anaesthetic breathing systems, ventilator breathing systems, humidifiers or nebulizers. It applies to breathing sets and breathing tubes and patient end adaptors supplied already assembled and to those supplied as components and assembled in accordance with the manufacturer’s instructions. This International Standard is applicable to breathing sets which include special components (e.g. water traps) between the patient end and machine end which are supplied already assembled. This International Standard is not applicable to breathing sets and breathing tubes for special purposes. EXAMPLE 1 Ventilators having special compliance, pressure or breathing frequency requirements. EXAMPLE 2 High Frequency Oscillatory Ventilation, (HFOV) or High Frequency Jet Ventilation (HFJV). EXAMPLE 3 Breathing sets and breathing tubes with special connectors for neonatal ventilation. Provision is made for coaxial and related bifurcated, double-lumen, or multiple-lumen breathing sets and breathing tubes suitable for use with patient end adaptors. NOTE 1 Examples of various types of breathing sets with patient end adaptors are depicted in Annex A. Requirements for exhalation valves, exhaust valves, adjustable pressure-limiting (APL) valves, heat and moisture exchangers (HMEs), breathing filters, and reservoir bags, if provided, are not covered by this International Standard. NOTE 2 ISO 80601-2-12, ISO 80601-2-13, ISO 9360-1[3], ISO 23328-2[4], and ISO 5362[1] cover these. NOTE 3 Certain aspects of heated-wire breathing tubes are discussed in ISO 8185[2].

CSA Preface This is the second edition of CSA ISO 5367-19, Anaesthetic and respiratory equipment — Breathing sets and connectors, which is an adoption without modification of the identically titled ISO (International Organization for Standardization) Standard 5367 (fifth edition, 2014-10-15). It supersedes the previous edition published in 2014 as CAN/CSA-ISO 5367, Breathing tubes intended for use with anaesthetic apparatus and ventilators (adopted ISO 5367:2000). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope *This International Standard specifies basic requirements for breathing sets and breathing tubes intended to be used with anaesthetic breathing systems, ventilator breathing systems, humidifiers or nebulizers. It applies to breathing sets and breathing tubes and patient end adaptors supplied already assembled and to those supplied as components and assembled in accordance with the manufacturer’s instructions. This International Standard is applicable to breathing sets which include special components (e.g. water traps) between the patient end and machine end which are supplied already assembled. This International Standard is not applicable to breathing sets and breathing tubes for special purposes. EXAMPLE 1 Ventilators having special compliance, pressure or breathing frequency requirements. EXAMPLE 2 High Frequency Oscillatory Ventilation, (HFOV) or High Frequency Jet Ventilation (HFJV). EXAMPLE 3 Breathing sets and breathing tubes with special connectors for neonatal ventilation. Provision is made for coaxial and related bifurcated, double-lumen, or multiple-lumen breathing sets and breathing tubes suitable for use with patient end adaptors. NOTE 1 Examples of various types of breathing sets with patient end adaptors are depicted in Annex A. Requirements for exhalation valves, exhaust valves, adjustable pressure-limiting (APL) valves, heat and moisture exchangers (HMEs), breathing filters, and reservoir bags, if provided, are not covered by this International Standard. NOTE 2 ISO 80601-2-12, ISO 80601-2-13, ISO 9360-1[3], ISO 23328-2[4], and ISO 5362[1] cover these. NOTE 3 Certain aspects of heated-wire breathing tubes are discussed in ISO 8185[2].

DocumentType
Standard
ISBN
978-1-4883-2143-6
Pages
52
ProductNote
This standard also refers to EN 556-1,EN 1041
PublisherName
Canadian Standards Association
Status
Current
Supersedes

Standards Relationship
ISO 5367:2014 Identical

View more information
£157.97
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.