• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 12541:2002

Current

Current

The latest, up-to-date edition.

Sanitary tapware - Pressure flushing valves and automatic closing urinal valves PN 10

Published date

04-12-2002

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Classification and Designation
   4.1 Classification of flushing valves
   4.2 Classification of urinal valves
   4.3 Designation
5 Marking
6 Materials
   6.1 Chemical and hygienic requirements
   6.2 Condition of exposed surfaces and
       quality of coating
7 Dimensional characteristics
   7.1 WC flushing valve
   7.2 Urinal valves
8 Leaktightness characteristics
   8.1 General
   8.2 Leaktightness tests
   8.3 Leaktightness tests - Summary table
9 Pressure resistance characteristics
   9.1 General
   9.2 Mechanical behaviour tests
   9.3 Mechanical behaviour tests - Summary table
10 Hydraulic and flow characteristics of WC flushing valves
   10.1 General
   10.2 Test method for WC flushing valves
   10.3 Outline of flow rate-time-volume-impact force test
        and requirements
   10.4 Summary of requirements
   10.5 Measurement of water hammer
11 Principle and verification of atmospheric pipe interrupters
   of WC flushing valves
   11.1 General
   11.2 Atmospheric pipe interrupter composition
   11.3 Installation conditions
   11.4 Verification of absence of water splashes
   11.5 Verification of operation at vacuum
12 Hydraulic or flow characteristics of urinal valves
   12.1 General
   12.2 Test method for urinal valves
   12.3 Requirements
13 Operating force
14 Mechanical endurance characteristics
   14.1 General
   14.2 WC flushing valves
   14.3 Urinal valves
15 Acoustic characteristics
   15.1 General
   15.2 Procedure
   15.3 Requirements

This Eruopean Standard applies to flushing valves for WCs and valves for urinalswith automatic hydraulic closure, intended for: -WC pans prEN 997; -urinals; -siphon action urinals. It does not apply to no-contact detection valves. It is intended to specify: -the marking, identification, physical-chemical, dimensio- nal leaktightness, pressure behaviour, hydraulic, mechanical endurance and acoustic characteristics to determine requirement for the atmospheric interrup- ters (air gaps) which shall form an integral part of WC and urinal flushing valves with automatic closure.

Committee
CEN/TC 164
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
PN EN 12541 : 2005 Identical
I.S. EN 12541:2003 Identical
NF EN 12541 : 2003 Identical
NEN EN 12541 : 2003 Identical
UNI EN 12541 : 2003 Identical
BS EN 12541:2002 Identical
SN EN 12541 : 2002 Identical
NS EN 12541 : 1ED 2003 Identical
UNE-EN 12541:2003 Identical
NBN EN 12541 : 2003 Identical
DIN EN 12541:2003-03 Identical

BS EN 15091:2013 Sanitary tapware. Electronic opening and closing sanitary tapware
BS EN 14453:2005 Devices to prevent pollution by backflow of potable water. Pipe interrupter with permanent atmospheric vent DN 10 to DN 20. Family D, type C
DIN EN 15091:2014-03 SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE
DIN EN 14453:2005-08 Devices to prevent pollution by backflow of potable water - Pipe interrupter with permanent atmospheric vent DN 10 to DN 20 - Family D, type C; German version EN 14453:2005
I.S. EN 15091:2013 SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE
UNE-EN 15091:2014 Sanitary tapware - Electronic opening and closing sanitary tapware
UNI EN 15091 : 2014 SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE
12/30260007 DC : 0 BS EN 15091 - SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE
PREN 15091 : DRAFT 2012 SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE
DIN EN 15091 E : 2014 SANITARY TAPWARE - ELECTRONIC OPENING AND CLOSING SANITARY TAPWARE
DIN EN 14453 E : 2005 DEVICES TO PREVENT POLLUTION BY BACKFLOW OF POTABLE WATER - PIPE INTERRUPTER WITH PERMANENT ATMOSPHERIC VENT DN 10 TO DN 20 - FAMILY D, TYPE C
EN 15091:2013 Sanitary tapware - Electronic opening and closing sanitary tapware
EN 14453:2005 Devices to prevent pollution by backflow of potable water - Pipe interrupter with permanent atmospheric vent DN 10 to DN 20 - Family D, type C

ISO 3822-1:1999 Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement
ISO 3822-4:1997 Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 4: Mounting and operating conditions for special appliances
EN ISO 3822-4:1997 Acoustics - Laboratory tests on noise emission from appliances and equipment used in water supply installations - Part 4: Mounting and operating conditions for special appliances
ISO 65:1981 Carbon steel tubes suitable for screwing in accordance with ISO 7-1
EN ISO 3822-1:1999/A1:2008 ACOUSTICS - LABORATORY TESTS ON NOISE EMISSION FROM APPLIANCES AND EQUIPMENT USED IN WATER SUPPLY INSTALLATIONS - PART 1: METHOD OF MEASUREMENT
PREN 13407 : DRAFT 2014 WALL-HUNG URINALS - FUNCTIONAL REQUIREMENTS AND TEST METHODS
ISO 228-1:2000 Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation
EN 248:2002 Sanitary tapware - General specification for electrodeposited coatings of Ni-Cr

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.