EN 14662-4:2005

Current

Current

The latest, up-to-date edition.

Ambient air quality - Standard method for measurement of benzene concentrations - Part 4: Diffusive sampling followed by thermal desorption and gas chromatography

Published date

18-05-2005

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Method description
  4.1 Principle
  4.2 Reagents and materials
  4.3 Apparatus
  4.4 Sample tube conditioning
  4.5 Sampling
  4.6 Procedure
  4.7 Calculation of mass concentration of benzene
  4.8 Report
5 Determination of measurement uncertainty
  5.1 Introduction
  5.2 Parameters contributing to measurement uncertainty
6 Recommendations for use
Annex A (informative) Diffusive uptake rates for benzene on
                      sorbent tubes (without membrane)
Annex B (informative) Description of sorbent types
Annex C (informative) Guidance on sorbent selection
Annex D (informative) Guide on sorbent use
Annex E (informative) Assessment of performance indicators and
                      uncertainty contributions
Annex F (informative) Performance characteristics
Bibliography

This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union reference method for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period.This part of EN 14662 gives general guidance for the sampling and analysis of benzene in air by diffusive sampling, thermal desorption and capillary gas chromatography. This part of EN 14662 is valid for the measurement of benzene in a concentration range of approximately 0,5 mg/m3 to 50 mg/m3 in an air sample typically collected over a period of 14 days. The upper limit of the useful range is set by the sorptive capacity of the sorbent and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sorbent. Artefacts are typically sub ng for sorbents such as graphitised carbon, but higher levels of aromatic hydrocarbons have been noted in other sorbents.

Committee
CEN/TC 264
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 6144:2003 Gas analysis Preparation of calibration gas mixtures Static volumetric method
EN 838:2010 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
ISO 5725-3:1994 Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method
ISO 16017-2:2003 Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling
EN ISO 16017-2:2003 Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ISO 16017-2:2003)
ISO Guide 30:2015 Reference materials Selected terms and definitions
EN 13528-2:2002 Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 2: Specific requirements and test methods
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
EN 13528-3:2003 Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 3: Guide to selection, use and maintenance
ISO 3534-1:2006 Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.