• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 1999-1-3:2007

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Eurocode 9: Design of aluminium structures – Part 1-3: Structures susceptible to fatigue

Withdrawn date

31-03-2010

Published date

23-05-2007

1.1.1Scope of EN 1999(1) P EN 1999 applies to the design of buildings and civil engineering and structural works in aluminium. It complies with the principles and requirements for the safety and serviceability of structures, the basis of their design and verification that are given in EN 1990 – Basis of structural design.(2) EN 1999 is only concerned with requirements for resistance, serviceability, durability and fire resistance of aluminium structures. Other requirements, e.g. concerning thermal or sound insulation, are not considered. (3) EN 1999 is intended to be used in conjunction with:-EN 1990 Basis of structural design-EN 1991 Actions on structures-European Standards for construction products relevant for aluminium structures-EN 1090-1: Execution of steel structures and aluminium structures - Part 1: Conformity assessment of structural components ) -EN 1090-3: Execution of steel structures and aluminium structures – Part 3: Technical requirements for aluminium structures ) (4) EN 1999 is subdivided in five parts:EN 1999-1-1Design of Aluminium Structures: General structural rulesEN 1999-1-2Design of Aluminium Structures: Structural fire designEN 1999-1-3Design of Aluminium Structures: Structures susceptible to fatigueEN 1999-1-4Design of Aluminium Structures: Cold-formed structural sheetingEN 1999-1-5Design of Aluminium Structures: Shell structures1.1.2Scope of EN 1999-1-3(1) EN 1999-1-3 gives the basis for the design of aluminium alloy structures with respect to the limit state of fracture induced by fatigue.(2) EN 1999-1-3 gives rules for:-Safe life design; -damage tolerant design;-design assisted by testing.(3) EN 1999-1-3 is intended to be used in conjunction with EN 1090-3 -Technical requirements for the execution of aluminium structures- which contains the requirements necessary for the design assumptions to be met during execution of components and structures.(4) EN 1999-1-3 does not cover pre

Committee
CEN/TC 250
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn
SupersededBy

Standards Relationship
UNE-EN 1999-1-3:2007 Identical

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.