• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 55016-1-2:2014/A1:2018

Current

Current

The latest, up-to-date edition.

SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-2: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - COUPLING DEVICES FOR CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-1-2:2014/A1:2017)

Amendment of

EN 55016-1-2:2014

Published date

02-02-2018

Foreword
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Artificial networks for AC mains and other
  power ports
5 Current and voltage probes
6 Coupling units for conducted current immunity
  measurement
7 Coupling devices for measuring signal lines
8 The artificial hand and series RC element
9 CDNE for measurement of disturbance voltage
  in frequency range 30 MHz to 300 MHz
Annex A (normative) - Characteristics and their
        measurement, circuit schemes and examples
        of modern implementations of AMNs and
        other ANs for use with power or load ports of EUTs
Annex B (informative) - Construction, frequency range, and
        calibration of current probes
Annex C (informative) - Construction of the coupling units
        for current injection for the frequency range 0,15
        MHz to 30 MHz
Annex D (informative) - Principle of operation and examples
        of coupling units for conducted current immunity
        measurements
Annex E (normative) - Example and measurement of the
        parameters of the asymmetric artificial network (AAN)
Annex F (normative) - Example and measurement of the
        parameters of the AN for coaxial and other
        screened cables
Annex G (informative) - Construction and evaluation of
        capacitive voltage probe
Annex H (informative) - Rationale for the introduction of
        a minimum decoupling factor between mains and
        EUT/receiver ports for the V-AMN
Annex I (informative) - Rationale for the introduction of a
        phase tolerance for the V-AMN input impedance
Annex J (informative) - Example CDNE set-up diagrams
Annex K (normative) - Measurement of Delta-AN parameters
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Defines the characteristics and performance of equipment for the measurement of radio disturbance voltages and currents in the frequency range 9 kHz to 1 GHz.

Committee
CLC/TC 210
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
CISPR 16-2-1:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR TR 16-4-1:2009 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 55016-2-1:2014/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-1: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-2-1:2014/A1:2017)
EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)
CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.