• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 61010-2-033 : 2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 2-033: PARTICULAR REQUIREMENTS FOR HAND-HELD MULTIMETERS AND OTHER METERS, FOR DOMESTIC AND PROFESSIONAL USE, CAPABLE OF MEASURING MAINS VOLTAGE (IEC 61010-2-033:2012)

Superseded date

18-11-2021

Published date

12-01-2013

FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Tests
5 Marking and documentation
6 Protection against electric shock
7 Protection against mechanical hazards
8 Resistance to mechanical stress
9 Protection against the spread of fire
10 Equipment temperature limits and resistance
    to heat
11 Protection against HAZARDS from fluids
12 Protection against radiation, including
    laser sources, and against sonic and ultrasonic
    pressure
13 Protection against liberated gases and
    substances, explosion and implosion
14 Components and subassemblies
15 Protection by interlocks
16 HAZARDS resulting from application
17 RISK assessment
101 Measuring circuits
Annexes
Annex K (normative) - Insulation requirements not
        covered by 6.7
Annex L (informative) - Index of defined terms
Annex AA (normative) - Measurement categories
Annex BB (informative) - Hazards pertaining to
         measurements performed in certain
         environments
Bibliography

Defines safety requirements for METERS.

Committee
SR 66
DevelopmentNote
To be read in conjunction with EN 61010-1. (06/2012)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

IEC 61557-5:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 5: Resistance to earth
IEC 61010-2-032:2012 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement
IEC 61557-10:2013 Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring and monitoring of protective measures
IEC 61010-2-030:2017 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits
IEC 61557-1:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
IEC 61557-2:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 2: Insulation resistance
EN 41003:2008 Particular safety requirements for equipment to be connected to telecommunication networks and/or a cable distribution system
IEC 61557-4:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding
IEC 61557-9:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems
IEC 61557-12:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD)
IEC 61557-7:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
IEC 61557-8:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems
IEC 61557-6:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems
IEC 61557-11:2009 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 11: Effectiveness of residual current monitors (RCMs) type A and type B in TT, TN and IT systems
IEC 61557-3:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance

View more information
Sorry this product is not available in your region.