EN IEC 60076-11:2018

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Power transformers - Part 11: Dry-type transformers

Superseded date

27-07-2019

Published date

26-10-2018

NEW!IEC 60076-11:2018 is available as IEC 60076-11:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60076-11:2018 applies to dry-type power transformers (including auto-transformers) having values of highest voltage for equipment up to and including 72,5 kV and at least one winding operating at greater than 1,1 kV. This document does not apply to:

- gas-filled dry-type transformers where the gas is not air;

- single-phase transformers rated at less than 5 kVA;

- polyphase transformers rated at less than 15 kVA;

- instrument transformers;

- starting transformers;

- testing transformers;

- traction transformers mounted on rolling stock;

- flameproof and mining transformers;

- welding transformers;

- voltage regulating transformers;

- small power transformers in which safety is a special consideration.

Where IEC standards do not exist for the transformers mentioned above or for other special transformers, this document may be applicable as a whole or in parts. This second edition cancels and replaces the first edition published in 2004 and constitutes a technical revision. The main changes with regard to the previous edition are as follows:

- Extension of the scope up to 72,5kV

- Enclosure management in regards of the performance

- Management of the dielectric and thermal features with altitude

- New climatic classes for a better adaptation of customers’ need

- Establishment of the relation between location and environmental classes

- For fire behaviour classes, limitation at 1000kVA and process of test more robust

- Introduction of Seismic class

- Recommendations for amorphous transformers

Keywords: dry-type transformers

Committee
CLC/TC 14
DocumentType
Standard
ProductNote
THIS STANDARD ALSO REFERS TO- EN 60071-1, EN 60076-3:2013, EN 60270, EN 60721-3-4 , EN 62271-202
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.