• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ENV 14138:2001

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Lead and lead alloys - Analysis by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma emission spectrometry (ICP-ES), after separation by co-precipitation

Withdrawn date

26-08-2022

Published date

12-12-2001

Foreword
1 Scope
2 Normative references
3 Principle
   3.1 Preparation of the test solution
   3.2 Instrumental techniques
       3.2.1 Flame atomic absorption spectrometry (FAAS)
       3.2.2 Inductively coupled plasma emission
             spectrometry (ICP-ES)
4 Apparatus
   4.1 General
   4.2 Volumetric glassware
   4.3 Filtration system
   4.4 Instruments
       4.4.1 Flame atomic absorption spectrometer
       4.4.2 Inductively coupled plasma emission
             spectrometer
5 Reagents
   5.1 General
   5.2 Nitric acid (HNO[3])
       5.2.1 Concentrated nitric acid
       5.2.2 Nitric acid 1:1 (V/V)
       5.2.3 Nitric acid 1:2 (V/V)
   5.3 Hydrochloric acid (HCI)
       5.3.1 Concentrated hydrochloric acid
       5.3.2 Hydrochloric acid 1:1 (V/V)
   5.4 Ammonia solution
   5.5 Pure lead
   5.6 Manganese nitrate solution
   5.7 Potassium permanganate solution
   5.8 Standard solutions
       5.8.1 Standard solutions (1 g/l)
       5.8.2 Standard solutions (100 mg/l)
       5.8.3 Standard solutions (10 mg/l)
       5.8.4 Multi-element solutions (either 10 mg/l or
             100 mg/l)
6 Sampling and sample preparation
7 Procedure
   7.1 Preparation of the test solution
       7.1.1 Dissolution
       7.1.2 Co-precipitation with manganese dioxide
       7.1.3 Test solution
   7.2 Preparation of the synthetic test solution
   7.3 Preparation of the blank test solution
   7.4 Preparation of the calibration solutions
8 Determination of elements by FAAS
   8.1 General
   8.2 Calibration and measurement of the test solution
   8.3 Expression of results
       8.3.1 Analyte recovery rate
       8.3.2 Analyte content in the sample
9 Determination of elements by ICP-ES
   9.1 General
   9.2 Calibration and measurement of the test solution
   9.3 Expression of results
       9.3.1 Analyte recovery rate
       9.3.2 Analyte content in the sample
10 Test report
Bibliography

This European Prestandard specifies methods using flame atomic absorption spectrometry (FAAS) and inductively coupled plasma emission spectrometry (ICP-ES) for the determination of elements at low content in lead for the ranges given in Table 1.Higher contents than those listed in Table 1 should be determined according to ENV 13800.These methods are intended as the definitive methods in case of dispute for the determination of elements at low content in lead. They are also recommended for the analysis of Certified Reference Materials (CRM) and Reference Materials (RM) which are used in analysis according to ENV 12908.

Committee
CEN/TC 306
DocumentType
Standard Recommendation
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

Standards Relationship
DD ENV 14138:2001 Identical
UNI ENV 14138 : 2003 Identical
DIN V ENV 14138:2002-03 Identical
NEN NVN ENV 14138 : 2002 Identical
I.S. ENV 14138:2002 Identical
XP ENV 14138 : 2002 XP Identical
NBN ENV 14138 : 2002 Identical

DIN 17640-1:2004-02 Lead alloys for general purposes

EN 12402 : 1999 LEAD AND LEAD ALLOYS - METHODS OF SAMPLING FOR ANALYSIS
ISO 1042:1998 Laboratory glassware One-mark volumetric flasks
ISO 648:2008 Laboratory glassware — Single-volume pipettes
EN ISO 1042 : 1999 LABORATORY GLASSWARE - ONE-MARK VOLUMETRIC FLASKS
ENV 14029:2001 Lead and lead alloys - Analysis by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma emission spectrometry (ICP-ES), after separation of the lead matrix
ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
EN ISO 3696:1995 Water for analytical laboratory use - Specification and test methods (ISO 3696:1987)
ENV 13800:2000 Lead and lead alloys - Analysis by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma emission spectrometry (ICP-ES), without separation of the lead matrix
ENV 12908:1997 Lead and lead alloys - Analysis by Optical Emission Spectrometry (OES) with spark excitation

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.