• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

I.S. EN 62199:2004

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

BUSHINGS FOR D.C. APPLICATION

Available format(s)

Hardcopy , PDF

Withdrawn date

20-02-2021

Language(s)

English

Published date

01-01-2004

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Ratings
   4.1 Rated voltages
   4.2 Insulation levels
   4.3 Rated currents
   4.4 Minimum nominal creepage distance
5 Operating conditions
   5.1 General
   5.2 Factors affecting the design, testing and application
6 General requirements
   6.1 List of variables
   6.2 Nameplate markings
7 Test requirements
   7.1 General requirements
   7.2 Test classification
8 Type tests
   8.1 Dry power-frequency voltage withstand test with
        partial discharge measurement
   8.2 Dry lightning impulse voltage withstand test (BIL)
   8.3 Dry or wet switching impulse voltage withstand
   8.4 Temperature rise test
   8.5 Cantilever load withstand test
   8.6 Tightness test on liquid-filled, compound-filled
        and liquid-insulated bushings
   8.7 Internal pressure test on gas-filled, gas-insulated
        and gas-impregnated bushings
   8.8 Verification of dimensions
9 Routine tests
   9.1 Measurement of dielectric dissipation factor
        (tan delta) and capacitances
   9.2 Dry lightning impulse voltage withstand test (BIL)
   9.3 Dry power-frequency voltage withstand test with
        partial discharge measurement
   9.4 DC applied voltage withstand test with partial
        discharge measurement
   9.5 Polarity reversal test with partial discharge
        measurement
   9.6 Test of tap insulation
   9.7 Internal pressure test on gas-filled, gas-insulated
        and gas-impregnated bushings
   9.8 Tightness test on liquid-filled, compound-filled
        and liquid-insulted bushings
   9.9 Tightness test on gas-filled, gas-insulated and
        gas-impregnated bushings
   9.10 Tightness test at the flange or other fixing device
   9.11 Visual inspection and dimensional check
10 Special tests
   10.1 Artificial pollution test
   10.2 Even wetting d.c. voltage test
   10.3 Uneven wetting d.c. voltage test
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications
Bibliography

Applicable to outdoor and indoor bushings of any voltage used on d.c. systems, of capacitance graded or gas insulated types for use as components of oil-filled converter transformers and smoothing reactors, as well as air-to-air d.c. bushings.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
63
PublisherName
National Standards Authority of Ireland
Status
Withdrawn
SupersededBy

Standards Relationship
BS EN 62199:2004 Identical
EN 62199:2004 Identical
IEC 62199:2004 Identical
DIN EN 62199 : 2005 Identical
NF EN 62199 : 2004 Identical
NBN EN 62199 : 2005 Identical
UNE-EN 62199:2005 Identical

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
IEC TS 61462:1998 Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations
IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
IEC TS 61245:2015 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC TS 61463:2016 Bushings - Seismic qualification

View more information
£90.60
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.