• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

IEC 61017-1:1991

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Portable, transportable or installed X or gamma radiation ratemeters for environmental monitoring - Part 1: Ratemeters

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

10-02-2016

Language(s)

English - French

Published date

30-04-1991

Contents
Foreword
Preface
Chapter I - General
1. Scope
2. Object
3. Terminology
    3.1 Definitions
4. Units
Chapter II - Assembly Design
5. General characteristics
    5.1 Effective range of measurement
    5.2 Ease of decontamination
    5.3 Portability
    5.4 Installed assemblies
Chapter III - Test Procedures
6. General test conditions
    6.1 Nature of tests
    6.2 Reference conditions and standard test conditions
    6.3 Tests performed under standard test conditions
    6.4 Tests performed with variation of influence quantities
    6.5 Statistical fluctuations
    6.6 Reference gamma radiation
7. Radiation characteristics
    7.1 Relative intrinsic error
    7.2 Variation of response with radiation energy
    7.3 Variation of response with angle of incidence
    7.4 Response to other ionizing radiations
    7.5 Overload characteristics
8. Electrical characteristics
    8.1 Statistical fluctuations
    8.2 Response time
    8.3 Inter-relationship between response time and
         statistical fluctuations
    8.4 Zero drift
    8.5 Warm-up time
    8.6 Power supplies
9. Mechanical characteristics
    9.1 Mechanical shocks
    9.2 Orientation of assembly (geotropism)
10. Environmental characteristics
    10.1 Ambient temperature
    10.2 Relative humidity
    10.3 Atmospheric pressure
    10.4 Sealing
    10.5 External electromagnetic fields
    10.6 External magnetic fields
    10.7 Storage
Chapter IV - Documentation
11. Documentation
    11.1 Type test report
    11.2 Certificate
12. Operation and maintenance manual
Table I - Reference conditions and standard test conditions
Table II - Tests performed with variations of influence
quantities
Appendix A - Calibration of air kerma ratemeters

Applies to portable, transportable or installed assemblies intended to measure environmental air kerma rates from 30 nGy h-1 to 10 µGy h-1 due to X or gamma radiation of energy between 50 keV and 1,5 MeV. Specifies general characteristics, general test procedures radiation characteristics, electrical, mechanical, safety and environmental characteristics as well as the identification certificate.

DevelopmentNote
Stability Date: 2013. (10/2012)
DocumentType
Standard
Pages
57
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

Standards Relationship
CEI 45-49 : 1997 Identical
BS EN 61067-1:1997 Identical

12/30227555 DC : 0 BS EN 60860 ED 2.0 - RADIATION PROTECTION INSTRUMENTATION WARNING EQUIPMENT FOR CRITICALITY ACCIDENTS
BS IEC 60860:2014 Radiation protection instrumentation. Warning equipment for criticality accidents
IEC 61584:2001 Radiation protection instrumentation - Installed, portable or transportable assemblies - Measurement of air kerma direction and air kerma rate
BS IEC 61584:2001 Radiation protection instrumentation. Installed, portable or transportable assemblies. Measurement of air kerma direction and air kerma rate
IEC 60860:2014 Radiation protection instrumentation - Warning equipment for criticality accidents

View more information
£177.95
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.