MIL-DTL-16036 Revision M:2013
Current
The latest, up-to-date edition.
SWITCHGEAR, POWER, LOW VOLTAGE, NAVAL SHIPBOARD
English
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - APPENDIX FOR DRAWING TECHNICAL
REQUIREMENTS
Gives the requirements for electrical power dead-front, deck-mounted, low voltage switchgear for Naval shipboard use.
Committee |
FSC 6110
|
DevelopmentNote |
Supersedes MIL S 16036 (K) (02/2006)
|
DocumentType |
Standard
|
Pages |
97
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
MIL-DTL-32529 Base Document:2015 | POWER ELECTRONIC CONVERSION EQUIPMENT, NAVAL SHIPBOARD |
MIL-PRF-32150 Revision B:2013 | STATIC AUTOMATIC BUS TRANSFER SWITCH (SABT) ON SURFACE AND SUBMARINE NAVAL VESSELS |
MIL-PRF-17773 Revision D:2015 | SWITCH, BUS TRANSFER, ELECTRIC POWER, AUTOMATIC |
MIL-STD-2003-1 Revision A:2009 | ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (CABLE) |
MIL-DTL-32485 Base Document:2013 | CIRCUIT BREAKERS, VACUUM TYPE (VCB), ELECTRIC POWER, MEDIUM VOLTAGE, ALTERNATING CURRENT, DRAW-OUT REMOVABLE CONSTRUCTION, WITHOUT INTERNAL OVERCURRENT PROTECTION |
MIL-STD-2003-2 Revision A:2009 | ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (EQUIPMENT) |
MIL-DTL-917 Revision F:2014 | ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR |
MIL-DTL-17587 Revision C:2007 | CIRCUIT BREAKERS, ACB, LOW VOLTAGE, ELECTRIC POWER, AIR, REMOVABLE CONSTRUCTION, GENERAL SPECIFICATION FOR |
MIL-F-21346 Revision B:1976 | FUSEHOLDERS, BLOCK, AND SHROUD TYPE, AND ASSOCIATED FUSE CLIPS; GENERAL SPECIFICATION FOR |
IEEE C37.20.1-2015 REDLINE | IEEE Standard for Metal-Enclosed Low-Voltage (1000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear |
MIL-PRF-19207-23 Revision M:2014 | Fuseholders, Extractor Post Type, Blown Fuse Indicating, Type FHL34W |
MIL-W-19088 Base Document:1955 | WATTMETER, SWITCHBOARD TYPE 4-1/2 INCH |
ASTM D 709 : 2017 : REDLINE | Standard Specification for Laminated Thermosetting Materials |
MIL-PRF-19207 Revision G:2013 | Fuseholders, Extractor Post Type, Blown Fuse, Indicating and Nonindicating, General Specification for |
MIL M 16034 : A | METER, ELECTRICAL-INDICATING (SWITCHBOARD AND PORTABLE TYPES) |
MIL-T-16315 Revision D:1994 | TRANSFORMER, POWER, STEP DOWN (MISCELLANEOUS, NAVAL SHIPBOARD USE) (NAVY) |
NEMA HP 6 : 2013 | ELECTRICAL AND ELECTRONIC SILICONE AND SILICONE BRAIDED INSULATED, HOOK-UP WIRE, TYPES S (600 V), ZHS (600 V), SS (1000 V), ZHSS (1000 V), AND SSB BRAIDED (1000 V) |
MIL-DTL-2212 Revision K:2014 | CONTACTORS AND CONTROLLERS, ELECTRIC MOTOR AC OR DC, AND ASSOCIATED SWITCHING DEVICES |
CFR 29(PTS1900-1910) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
MIL-HDBK-46855 Revision A:1999 | HUMAN ENGINEERING PROGRAM - PROCESS AND PROCEDURES |
MIL E 917 : E | ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS (NAVAL SHIPBOARD USE) |
ASTM A 666 : 2015 : REDLINE | Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar |
MIL-DTL-24552 Revision B:2001 | TERMINALS AND SEALS, PLUGS AND SWITCH, CASUALTY POWER SYSTEMS, RECEPTACLE TYPE, GENERAL SPECIFICATION FOR |
MIL-C-17588 Revision E:1985 | CIRCUIT BREAKERS (AUTOMATIC - ALB) AND SWITCH, TOGGLE (CIRCUIT BREAKER, NON AUTOMATIC - NIB) AIR, INSULATED HOUSING, 125 VOLTS AND BELOW AC OR DC (NAVAL SHIPBOARD USE) |
MIL-S-16104 Revision B:1983 | |
MIL-DTL-28803 Revision C:2013 | DISPLAY, OPTOELECTRONIC, SEGMENTED READOUTS, BACKLIGHTED, GENERAL SPECIFICATION FOR |
MIL-DTL-21604 Revision G:2017 | Switches, Rotary, Multipole and Selector, General Specification for |
MIL-DTL-21604-5 Revision E:2017 | SWITCH, ROTARY, MULTIPOLE AND SELECTOR, 10 AMPERE, STYLE JR |
MIL-R-24563 Base Document:1977 | RELAY, ALTERNATING CURRENT, POWER-SENSING |
MIL-S-24188 Base Document:1965 | SYNCHRONIZING CONTROL EQUIPMENT, 6O CYCLES, 45O VOLTS, NAVAL SHIPBOARD |
MIL-DTL-1222 Revision J:2000 | STUDS, BOLTS, SCREWS AND NUTS FOR APPLICATIONS WHERE A HIGH DEGREE OF RELIABILITY IS REQUIRED; GENERAL SPECIFICATION FOR |
ASTM B 221 : 2014 : REDLINE | Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes |
MIL-E-22118 Revision B:1974 | ENAMEL, ELECTRICAL INSULATING |
A-A-59125-2 Base Document:1997 | TERMINAL BOARDS, MOLDED, BARRIER SCREW TYPE, CLASS 38TB |
ASTM B 121/B121M : 2016 : REDLINE | Standard Specification for Leaded Brass Plate, Sheet, Strip, and Rolled Bar |
MIL-PRF-19207-1 Revision K:2013 | Fuseholders, Extractor Post Type, Blown Fuse Indicating, Types FHL10U and FHL10G |
DOD STD 2003 : 0 | ELECTRIC PLANT INSTALLATION - STANDARD METHODS FOR SURFACE SHIP AND SUBMARINES |
MIL-PRF-19207-21 Revision M:2014 | Fuseholders, Extractor Post Type, Blown Fuse Indicating, Non-EMI/RFI Shielded and EMI/RFI Shielded, Type FHL32W and Type FHL32WS |
NASM17830:2017 | NUT, SELF-LOCKING, HEXAGON-REGULAR, 250 DEGREES F AND 450 DEGREES F, NON-METALLIC INSERT, 300 SERIES CRES |
MIL-I-1361 Revision C:1985 | INSTRUMENT AUXILIARIES, ELECTRICAL MEASURING, SHUNTS, RESISTORS, AND TRANSFORMERS |
MIL-PRF-28750 Revision J:2017 | RELAYS, SOLID STATE, GENERAL SPECIFICATION FOR |
MIL-L-3661-38 Revision A:1968 | HOUSING, INDICATOR-LIGHT, STYLE LH80 |
MIL-R-19523 Revision B:1990 | RELAY, CONTROL, NAVAL SHIPBOARD |
MIL-DTL-3661 Revision D:2013 | Lampholders, Indicator Lights, Indicator Light Housings, and Indicator Light Lenses, General Specification for |
MIL-R-2729 Revision D:1992 | REGULATOR EXCITER SYSTEMS, VOLTAGE, A.C. GENERATOR, NAVAL SHIPBOARD USE |
A-A-59125-9 Base Document:1997 | TERMINAL BOARDS, MOLDED, BARRIER STUD TYPE, CLASS 3TB |
MS17832 Revision A:1970 | OPERATING WRENCH BUS DISCONNECT SYMBOL 1485 |
MIL-I-3158 Revision D:1968 | INSULATION TAPE, ELECTRICAL GLASS FIBER [RESIN FILLED] AND CORD, FIBROUS GLASS |
MIL-PRF-19207-24 Revision M:2014 | Fuseholders, Extractor Post Type, Blown Fuse Indicating, Non-EMI/RFI Shielded and EMI/RFI Shielded, Type FHL35W and Type FHL35WS |
MIL C 17587 : B | CIRCUIT BREAKER, LOW VOLTAGE, ELECTRIC POWER, AIR, OPEN FRAME, REMOVABLE CONSTRUCTION |
A-A-208 Revision C:2012 | INK, MARKING, STENCIL, OPAQUE, (POROUS AND NON-POROUS SURFACES) |
MIL-DTL-16878 Revision H:2012 | WIRE, ELECTRICAL, INSULATED, GENERAL SPECIFICATION FOR |
MS17831 Revision C:1968 | BUS DISCONNECT QUICK OPENING SYMBOL 1484 |
MIL-STD-461 Revision G:2015 | REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT |
SAE AS 7928 : 2011 | TERMINALS, LUG: SPLICES, CONDUCTOR: CRIMP STYLE, COPPER, GENERAL SPECIFICATION FOR |
MIL-V-23151 Revision B:1967 | VOLTMETER, EXPANDED SCALE SWITCHBOARD TYPE (NAVAL SHIPBOARD USE) |
MIL S 901 : D | SHOCK TESTS, HI [HIGH IMPACT] SHIPBOARD MACHINERY, EQUIPMENT AND SYSTEMS, REQUIREMENTS FOR |
ASTM B 209 : 2014 : REDLINE | Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate |
MIL-STD-108 Revision E:1966 | DEFINITION OF AND BASIC REQUIREMENT FOR ENCLOSURE FOR ELECTRIC AND ELECTRONIC EQUIPMENT |
MIL-M-16125 Revision C:1963 | METERS, ELECTRICAL, FREQUENCY |
MIL-PRF-19207-3 Revision L:2017 | Fuseholders, Extractor Post Type, Blown Fuse Indicating, Types FHL12U and FHL12G |
MIL C 17361 : F | CIRCUIT BREAKERS, AIR, ELECTRIC, INSULATED HOUSING (SHIPBOARD USE) |
A-A-59125 Revision B:2012 | Terminal Boards, Molded, Barrier Screw and Stud Types and Associated Accessories |
MIL-T-15377 Revision F:1979 | TEMPERATURE MONITOR EQUIPMENT, NAVAL SHIPBOARD |
MIL-PRF-19207-5 Revision L:2013 | Fuseholders, Extractor Post Type, Blown Fuse Indicating, Type FHL14G |
DOD S 17773 : B | SWITCHES, BUS TRANSFER, ELECTRIC POWER, AUTOMATIC AND MANUAL (METRIC) |
MIL-PRF-19207-22 Revision L:2014 | Fuseholders, Extractor Post Type, Blown Fuse Indicating, Type FHL33W |
MIL-DTL-24552-2 Revision B:2001 | TERMINALS AND SEALS, PLUGS AND SWITCH, CASUALTY POWER, RECEPTACLE TYPE, UPPER AND LOWER RISER, 200-AMPERE, 450-VOLT, ALTERNATING CURRENT, THREE-PHASE, SYMBOL NO. 1047 |
MIL-P-15024-5 Base Document:1971 | PLATE, IDENTIFICATION |
MIL-HDBK-470 Revision A:1997 | DESIGNING AND DEVELOPING MAINTAINABLE PRODUCTS AND SYSTEMS - VOLUME 1 |
TT-P-645 Revision C:2013 | PAINT, ALKYD TYPE, FORMULA NUMBER 84 |
MIL-DTL-15024 Revision F:1997 | Plates and Tags for Identification of Equipment, General Specification for |
MIL-STD-1671 Base Document:1975 | SCHEMATIC WIRING DIAGRAM (EXTERNAL DC POWER CONNECTOR, AIRCRAFT) |
A-A-59781 Base Document:2005 | LIGHT EMITTING DIODES FOR USE AS INDICATOR LIGHTS |
MIL-C-11796 Revision C:1986 | CORROSION PREVENTIVE COMPOUND, PETROLATUM, HOT APPLICATION |
MIL-I-24391 Revision C:1990 | INSULATION TAPE, ELECTRICAL, PLASTIC, PRESSURE SENSITIVE |
MIL-DTL-24552-1 Revision B:2001 | TERMINALS AND SEALS, PLUGS AND SWITCH, CASUALTY POWER, RECEPTACLE TYPE, BACK CONNECTED 200-AMPERE, 450-VOLT, ALTERNATING CURRENT, THREE-PHASE, SYMBOL NO. 1046 |
MIL-PRF-15160 Revision K:2013 | Fuses, Instrument, Power, and Telephone General Specification for |
MIL-DTL-15090 Revision E:2010 | ENAMEL, EQUIPMENT, LIGHT GRAY, (NAVY FORMULA NO. 111) |
MIL-I-631 Revision D:1961 | INSULATION, ELECTRICAL, SYNTHETIC - RESIN COMPOSITION, NONRIGID |
MIL-PRF-19207-2 Revision J:2013 | Fuseholders, Extractor Post Type, Blown Fuse Indicating, Types FHL11U and FHL11G |
MIL-T-15108 Revision C:1975 | TRANSFORMERS, POWER, STEP DOWN, SINGLE PHASE, 60 HERTZ, 1 KILOVOLTAMPERE APPROXIMATE MINIMUM RATING, DRY TYPE, NAVAL SHIPBOARD |
MIL-I-16103 Revision F:1983 | INDICATOR, PHASE SEQUENCE, SWITCHBOARD & PANEL |
TT-C-490 Revision F:2013 | CHEMICAL CONVERSION COATINGS AND PRETREATMENTS FOR METALLIC SUBSTRATES (BASE FOR ORGANIC COATINGS) |
MIL-DTL-15109 Revision D:2001 | RESISTORS AND RHEOSTATS, NAVAL SHIPBOARD |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.