• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

UNI EN 13084-4 : 2006

Current

Current

The latest, up-to-date edition.

FREE-STANDING CHIMNEYS - PART 4: BRICK LINERS - DESIGN AND EXECUTION

Published date

16-02-2006

Foreword
1 Scope
2 Normative references
3 Terms, definitions and symbols
  3.1 Terms and definitions
  3.2 Symbols
4 Material
  4.1 General
  4.2 Brickwork
      4.2.1 General
      4.2.2 Thermal effects
      4.2.3 Classification and chemical attack
  4.3 Insulation
5 General design requirements
  5.1 General
  5.2 Minimum wall thickness
  5.3 Liner supports
  5.4 Openings
  5.5 Ventilation
  5.6 Protective coatings
  5.7 Accessories
      5.7.1 Joints
      5.7.2 Compensators
      5.7.3 Ducts and fans
6 Structural design
  6.1 Actions
      6.1.1 General
      6.1.2 Wind actions
      6.1.3 Seismic actions
      6.1.4 Thermal effects
      6.1.5 Internal pressure and explosions
  6.2 Resistances
  6.3 Verification
      6.3.1 Ultimate limit state
      6.3.2 Serviceability limit state
      6.3.3 Stress calculations in the ultimate limit state
      6.3.4 Elastic stability
7 Execution
  7.1 Imperfections
  7.2 Tolerances
8 Inspection and maintenance
  8.1 General
  8.2 Inspection aspects
      8.2.1 Brick liner
      8.2.2 Insulation
  8.3 Frequency
  8.4 Performance
Annex A (informative) - Structural design of base supported
        liners
      A.1 General
      A.2 Elastic stability
          A.2.1 General
          A.2.2 Elastic stability of the uncracked tube
          A.2.3 Elastic stability of free standing vertical
                columns
          A.2.4 Elastic stability of a half tube
          A.2.5 Comparison of the three calculation methods
                and conclusions
Annex B (normative) - Openings
Annex C (informative) - Compensators
Annex D (informative) - Dynamic effects
Annex E (informative) - Strengthening - reinforced brickwork
      E.1 Steel bands, fitted outside the liner
          E.1.1 Stresses in the liner
          E.1.2 Plain steel bands
          E.1.3 Steel bands fitted with springs
      E.2 Reinforced brickwork
          E.2.1 General
          E.2.2 Dimensioning
          E.2.3 Materials
                E.2.3.1 Bricks
                E.2.3.2 Mortar
                E.2.3.3 Reinforcing steel
          E.2.4 Corrosion protection
          E.2.5 Execution
Annex F (informative) - Thermal effects
                        Thermal stresses
Annex G (informative) - Drying and start up
      G.1 New Liners
          G.1.1 General
          G.1.2 Externally insulated liners
          G.1.3 Uninsulated liners
      G.2 Old brick liners

This European Standard specifies special requirements and performance criteria for the design and construction of lining systems made of brickwork for free-standing industrial chimneys.

DocumentType
Standard
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Current

EN 13084-5:2005/AC:2006 FREE-STANDING CHIMNEYS - PART 5: MATERIAL FOR BRICK LINERS - PRODUCT SPECIFICATIONS
EN 1052-1:1998 Methods of test for masonry - Part 1: Determination of compressive strength
EN 13084-1:2007 Free-standing chimneys - Part 1: General requirements
EN 1052-2:2016/AC:2017 METHODS OF TEST FOR MASONRY - PART 2: DETERMINATION OF FLEXURAL STRENGTH

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.