Asphalt shingle application on roof slopes 1:6 and steeper

Available format(s)

Hardcopy , PDF

Language(s)

English, French

Published date

01-01-2014

Preface
1 Scope
2 Reference publications
3 Definitions
4 Materials
5 Roof preparation
6 Application of shingles
7 Flashings
8 Special procedures
Annex A (informative) - Roof sheathing
Annex B (informative) - Ventilation and application of
        asphalt shingles directly over insulation
Annex C (informative) - Other asphalt shingle installation
        precautions

Preface This is the first edition of CSA A123.51, Asphalt Shingle Application on Roof Slopes 1:6 and Steeper. It combines CSA CAN3-A123.51-M, Asphalt Shingle Application on Roof Slopes 1:3 and Steeper, and CSA CAN3-A123.52-M, Asphalt Shingle Application on Roof Slopes 1:6 to Less Than 1:3. It supersedes the second editions, published in 1985, of the two separate standards. It forms part of the series of CSA Group Standards on bituminous roofing materials (A123.1-M through A123.52-M) and is written in SI (metric) units. This Standard also supersedes the previous (Imperial) editions published in 1965. Scope 1.1 This Standard provides minimum requirements for the application of asphalt shingles on roofs with a slope of 1:6 and steeper. Portions of this Standard may not apply to laminated and/or dimensional shingles. The manufacturers of these shingles should be consulted for specific installation instructions. Note: Annex A is included to provide recommendations for acceptable substrates for shingles; Annex B, recommendations for acceptable ventilation below the shingle substrate, and recommendations on the application of asphalt shingles over insulation; and Annex C, other precautions for shingle installation. 1.2 The application of this Standard requires a working knowledge of applicable federal, provincial, and local building codes and regulations specifically concerning installation of asphalt roofing shingles. This Standard does not purport to address all building code requirements. For further requirements, the local authority having jurisdiction should be consulted. 1.3 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Preface This is the first edition of CSA A123.51, Asphalt Shingle Application on Roof Slopes 1:6 and Steeper. It combines CSA CAN3-A123.51-M, Asphalt Shingle Application on Roof Slopes 1:3 and Steeper, and CSA CAN3-A123.52-M, Asphalt Shingle Application on Roof Slopes 1:6 to Less Than 1:3. It supersedes the second editions, published in 1985, of the two separate standards. It forms part of the series of CSA Group Standards on bituminous roofing materials (A123.1-M through A123.52-M) and is written in SI (metric) units. This Standard also supersedes the previous (Imperial) editions published in 1965. Scope 1.1 This Standard provides minimum requirements for the application of asphalt shingles on roofs with a slope of 1:6 and steeper. Portions of this Standard may not apply to laminated and/or dimensional shingles. The manufacturers of these shingles should be consulted for specific installation instructions. Note: Annex A is included to provide recommendations for acceptable substrates for shingles; Annex B, recommendations for acceptable ventilation below the shingle substrate, and recommendations on the application of asphalt shingles over insulation; and Annex C, other precautions for shingle installation. 1.2 The application of this Standard requires a working knowledge of applicable federal, provincial, and local building codes and regulations specifically concerning installation of asphalt roofing shingles. This Standard does not purport to address all building code requirements. For further requirements, the local authority having jurisdiction should be consulted. 1.3 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

DevelopmentNote
Includes & supersedes CSA A123.52. (02/2014) French Edition issued on 01-08-2014. (08/2014)
DocumentType
Standard
ISBN
978-1-77139-208-2
Pages
38
PublisherName
Canadian Standards Association
Status
Current
Supersedes

CSA A123.1 : 2002 ASPHALT SHINGLES MADE FROM ORGANIC FELT AND SURFACED WITH MINERAL GRANULES / ASPHALT SHINGLES MADE FROM GLASS FELT AND SURFACED WITH MINERAL GRANULES
CSA A123.5 : 2016 ASPHALT SHINGLES MADE FROM GLASS FELT AND SURFACED WITH MINERAL GRANULES
CSA A123.1-A123.5 : 2005(R2015) ASPHALT SHINGLES MADE FROM ORGANIC FELT AND SURFACED WITH MINERAL GRANULES/ASPHALT SHINGLES MADE FROM GLASS FELT AND SURFACED WITH MINERAL GRANULES

ASTM D 7530/D7530M : 2017 : REDLINE Standard Specification for Self-Adhesive Glass Fiber Fabric Reinforced Polymer Modified Asphalt Steep Slope Roll Roofing Surfaced with Mineral Granules
CSA O437 SERIES : 1993 STANDARDS ON OSB AND WAFERBOARD
CGSB 51.32 : M77 SHEATHING, MEMBRANE, BREATHER TYPE
ASTM D 6164/D6164M : 2016 : REDLINE Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements
ASTM D 7505/D7505M : 2017 : REDLINE Standard Specification for Self-Adhesive Polyester Fabric Reinforced Polymer Modified Asphalt Steep Slope Roll Roofing Surfaced with Mineral Granules
CSA A123.1-A123.5 : 2005(R2015) ASPHALT SHINGLES MADE FROM ORGANIC FELT AND SURFACED WITH MINERAL GRANULES/ASPHALT SHINGLES MADE FROM GLASS FELT AND SURFACED WITH MINERAL GRANULES

View more information
US$125.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.