MIL-DTL-24643 Revision C:2009
Current
The latest, up-to-date edition.
Cables, Electric, Low Smoke, Halogen-Free, for Shipboard Use, General Specification for
10-01-2009
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
Specifies low smoke halogen-free electric cable for Navy shipboard applications.
This specification covers low smoke, halogen-free electric cable for Navy shipboard applications.
DevelopmentNote |
Supersedes MIL C 24643 (A). (09/2002)
|
DocumentType |
Standard
|
Pages |
190
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
MIL-DTL-2726-6 Revision C:2006 | Receptacle, Plug, Electrical, 3 - Pin Grounded, 40 - Ampere, 125 - Volt, Alternating Current (Symbol No. 1143.1) |
MIL-DTL-32529 Base Document:2015 | POWER ELECTRONIC CONVERSION EQUIPMENT, NAVAL SHIPBOARD |
MIL-DTL-2726-1 Revision C:2006 | Receptacle, Plug, Electrical, 2-Pin, 40-Ampere, 125-Volt, Direct Current (Symbol No. 715.1) |
MIL-PRF-32236 Base Document:2007 | GENERATOR, CHLORINE PORTABLE ELECTROLYTIC (PECG) |
MIL-PRF-32098 Revision A:2004 | ULTRAFILTRATION SYSTEM, 10-GALLON PER MINUTE OILY WASTE MEMBRANE (OWMS-10) |
MIL-PRF-30099 Revision A:2011 | TREATMENT SYSTEM, BLACKWATER AND COMBINED BLACKWATER/GRAYWATER, FOR SURFACE SHIPS |
NFPA 502 : 2017 | ROAD TUNNELS, BRIDGES, AND OTHER LIMITED ACCESS HIGHWAYS |
MIL-PRF-32227 Base Document:2006 | Flame Detector Zone Module (FDZM), Switch Closure Zone Module (SCZM), and Isolator, Advanced Fire and Smoke Sensor System (AFSSS) |
MIL-STD-2003-1 Revision A:2009 | ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (CABLE) |
MIL-STD-2003-3 Revision A:2009 | ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (PENETRATIONS) |
UFC 4-150-02 : Change 5 | UNIFIED FACILITIES CRITERIA - DOCKSIDE UTILITIES FOR SHIP SERVICE |
MIL-DTL-3124 Revision E:2014 | GENERATOR, ALTERNATING CURRENT, 60-HERTZ (NAVAL SHIPBOARD USE) |
MIL-PRF-32224 Base Document:2006 | Smoke Sensors, Ionization and Photoelectric, Advanced Fire and Smoke Sensor System (AFSSS) |
MIL-DTL-32525 Base Document:2016 | MAGAZINE, PORTABLE (SHIPBOARD) |
MIL-DTL-917 Revision F:2014 | ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR |
MIL-STD-2003-5 Revision A:2009 | ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (CONNECTORS) |
MIL-PRF-32167 Revision A:2006 | TRANSIENT VOLTAGE SURGE SUPPRESSOR (TVSS) |
MIL-PRF-32228 Base Document:2006 | Alarm Panel, Advanced Fire and Smoke Sensor System (AFSSS) |
MIL-STD-2003-4 Revision A:2009 | ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (CABLEWAYS) |
MIL-DTL-16556 Revision F:2017 | Valve, Solenoid, Three-Way Bypass ( Naval Shipboard Use ) |
MIL-DTL-2726-24 Revision C:2006 | Receptacle, Plug, Electrical, Connector, 25 - Ampere, 500 - Volt, 3- Phase Grounded (Symbol No. 707.1) |
MIL-DTL-24765 Revision B:2016 | POWER SUPPLY, UNINTERRUPTIBLE, STATIC (NAVAL SHIPBOARD) |
MIL-DTL-16377 Revision J:2014 | Fixtures, Lighting; and Associated Parts; Shipboard Use, General Specification for |
MIL-DTL-2726-25 Revision B:2006 | Receptacle, Electrical, Connector, 25-Ampere, 500-Volt, 3-Phase Grounded (Symbol No. 722.1) |
MIL-DTL-15103 Revision G:2015 | SALINITY INDICATING EQUIPMENT |
MIL-DTL-24705 Revision B:2010 | PENETRATORS, MULTIPLE CABLE, ELECTRIC CABLE, GENERAL SPECIFICATION FOR |
MIL-DTL-2726-5 Revision C:2005 | RECEPTACLE, PLUG, ELECTRICAL, 3-PIN GROUNDED, 40 - AMPERE, 450 - VOLT, ALTERNATING CURRENT (SYMBOL NO. 1140.1) |
MIL-PRF-32168 Base Document:2004 | VARIABLE SPEED DRIVE SYSTEM FOR INDUCTION AND SYNCHRONOUS MACHINES |
NEMA HP 8 : 2013 | ELECTRICAL AND ELECTRONIC CROSS-LINKED, MODIFIED LOW-SMOKE POLYOLEFIN (XLPO) INSULATED HOOK-UP WIRE, TYPES LS (RATED 105 DEGREES C; 600 V), ZHDM (RATED 90 DEGREES C; 600 V), ZHDH (RATED 90 DEGREES C; 600 V), ZH (RATED 125 DEGREES C; 600 V), AND ZHX (RATED 125 DEGREES C; 1000 V) |
MIL-STD-1310 Revision H:2009 | SHIPBOARD BONDING, GROUNDING, AND OTHER TECHNIQUES FOR ELECTROMAGNETIC COMPATIBILITY, ELECTROMAGNETIC PULSE (EMP) MITIGATION, AND SAFETY |
MIL-PRF-32226 Base Document:2006 | Flame Detector, Advanced Fire and Smoke Sensor System (AFSSS) |
MIL-DTL-2726-49 Revision F:2013 | RECEPTACLE, OUTLET, TRIPLE, ELECTRICAL, 40 - AMPERE, 450 - VOLT, 60 HERTZ, ALTERNATING CURRENT, 4 - POLE, PORTABLE, PLASTIC GROUNDED (SYMBOL NOS. 765.6, 765.7 AND 765.8) |
MIL-DTL-2726-2 Revision C:2006 | Receptacle, Plug, Electrical, 3 - Pin Grounded, 50 - Ampere, 250 - Volt, Direct Current (Symbol No. 716.1) |
MIL-DTL-2726-26 Revision D:2006 | Receptacle, Plug, Electrical 4 - Pin, 60 - Ampere, 208/117 - Volt, 3 - Phase Grounded (Symbol No. 728.1) |
MIL-DTL-2726-38 Revision D:2006 | RECEPTACLE, PLUG, ELECTRICAL, 15 - AMPERE, 125 - VOLT, BLADED TYPE, GROUNDED (SYMBOL NO. 1218.3) |
MIL-PRF-32225 Base Document:2006 | Heat Sensor, Advanced Fire and Smoke Sensor System (AFSSS) |
IEEE 45.8-2016 | IEEE Recommended Practice for Electrical Installations on Shipboard--Cable Systems |
MIL-DTL-28840 Revision D:2013 | CONNECTORS, ELECTRICAL, CIRCULAR, THREADED, HIGH SHOCK, HIGH DENSITY, SHIPBOARD, CLASS D, GENERAL SPECIFICATION FOR |
MIL-DTL-2726-3 Revision E:2016 | RECEPTACLE, PLUG, ELECTRICAL, 4-PIN GROUNDED, 40-AMPERE, 450-VOLT, ALTERNATING CURRENT, 60-HERTZ (SYMBOL NO. 717.1) |
MIL-DTL-28840-12 Revision F:2013 | CONNECTORS, ELECTRICAL, CIRCULAR, THREADED, HIGH SHOCK, HIGH DENSITY, SHIPBOARD, CRIMP CONTACTS, RECEPTACLE, BOX MOUNTING, CLASSES D, DS, P, T, TS, Z, AND ZS |
MIL-DTL-23928 Revision G:2014 | PANELS, ELECTRICAL, POWER DISTRIBUTION AND MANUAL TRANSFER, CIRCUIT BREAKER TYPE |
MIL-PRF-32007 Base Document:2003 | OILY WASTEWATER SEPARATION SYSTEM, 6.7-GALLON PER MINUTE NAVY INTEGRATED MEMBRANE SYSTEM (NIMS) |
MIL-DTL-16878-36 Revision A:2000 | WIRE, ELECTRICAL, LOW SMOKE, CROSSLINKED POLYOLEFIN (XLPO) INSULATED, 105 DEGREE C, 600 VOLTS |
MIL-DTL-2726-46 Revision B:2006 | Receptacle, Plug, Electrical, 100-Ampere, 250 - Volt, Direct Current, 3-Pole (Symbol No. 721.1) |
C22.2 NO. 245-17 | Marine shipboard cable |
UL 1685:4ED 2015-07 | Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables |
FED-STD-228 Revision A:2014 | TEST METHODS FOR CABLES AND WIRE, INSULATED |
MIL-DTL-5624 Revision W:2016 | TURBINE FUEL, AVIATION, GRADES JP-4 AND JP-5 |
ASTM B 174 : 2017 : REDLINE | Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors |
ASTM D 1248 : 2016 : REDLINE | Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable |
ASTM G 21 : 2015 : REDLINE | Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi |
ASTM D 1141 : 1998 : EDT 1 | Standard Practice for the Preparation of Substitute Ocean Water |
TIA/EIA 568-2 : C2009 AMD 1 2016 | COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 2: BALANCED TWISTED-PAIR TELECOMMUNICATIONS CABLING AND COMPONENTS STANDARDS |
MIL-PRF-17331 Revision K:2013 | LUBRICATING OIL, STEAM TURBINE AND GEAR, MODERATE SERVICE |
ASME B46.1 : 2009 | SURFACE TEXTURE (SURFACE ROUGHNESS, WAVINESS, AND LAY) |
MIL-DTL-16884 Revision P:2017 | FUEL, NAVAL DISTILLATE |
MIL-STD-2003-4 Revision A:2009 | ELECTRIC PLANT INSTALLATION STANDARD METHODS FOR SURFACE SHIPS AND SUBMARINES (CABLEWAYS) |
ASTM B 172 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors |
NES 713 : ISSUE 3 | DETERMINATION OF THE TOXICITY INDEX OF THE PRODUCTS OF COMBUSTION FROM SMALL SPECIMENS OF MATERIALS |
ISA MC96.1 : 1982 | TEMPERATURE MEASUREMENT THERMOCOUPLES |
MIL-Y-1140 Revision H:1972 | Yarn, Cord, Sleeving, Cloth, and Tape-Glass |
MIL-PRF-23699 Revision G:2014 | Lubricating Oil, Aircraft Turbine Engine, Synthetic Base, NATO Code Numbers: O-152, O-154, O-156, and O-167 |
NES 711 : ISSUE 2 | DETERMINATION OF THE SMOKE INDEX OF THE PRODUCTS OF COMBUSTION FROM SMALL SPECIMENS OF MATERIALS |
MIL DTL 17 : J | CABLES, RADIO FREQUENCY, FLEXIBLE AND SEMIRIGID, GENERAL SPECIFICATION FOR |
MIL-PRF-17672 Revision E:2010 | Hydraulic Fluid, Petroleum, Inhibited |
NEMA WC 26/EEMAC 201:2008 | Binational Wire and Cable Packaging Standard |
NEMA WC 61 : 2005(R2015) | TRANSFER IMPEDANCE TESTING |
ICEA T 28 562 : 2003(R2014) | TEST METHOD FOR MEASUREMENT OF HOT CREEP OF POLYMERIC INSULATIONS |
ASTM B 173 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors |
ASTM B 193 : 2016 : REDLINE | Standard Test Method for Resistivity of Electrical Conductor Materials |
MIL-I-631 Revision D:1961 | INSULATION, ELECTRICAL, SYNTHETIC - RESIN COMPOSITION, NONRIGID |
MIL C 572 : G | CORD, YARNS AND MONOFILAMENT ORGANIC SYNTHETIC FIBER |
ASTM D 470 : 2013 : REDLINE | Standard Test Methods for Crosslinked Insulations and Jackets for Wire and Cable |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.