W-F-1814 Revision D:2013
Current
The latest, up-to-date edition.
FUSES, CARTRIDGE, HIGH-INTERRUPTING CAPACITY
1. SCOPE AND CLASSIFICATION
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. QUALITY ASSURANCE PROVISIONS
5. PACKAGING
6. NOTES
Specifies the general requirements and test procedures for current-limiting and noncurrent-limiting, nonrenewable, cartridge fuses with interrupting capacity ratings of 100,000 or 200,000 rms symmetrical amperes.
Committee |
FSC 5920
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
W-F-1814-3 Revision D:2015 | FUSE, CARTRIDGE, HIGH INTERRUPTING CAPACITY, CLASS G (CURRENT-LIMITING) 480 VOLTS, 21-30 AMPERES |
W-F-1814-2 Revision D:2015 | FUSE, CARTRIDGE, HIGH INTERRUPTING CAPACITY, CLASS G (CURRENT-LIMITING) 600 VOLTS, 16-20 AMPERES |
W-F-1814-1 Revision D:2015 | FUSE, CARTRIDGE, HIGH INTERRUPTING CAPACITY, CLASS G (CURRENT-LIMITING) 600 VOLTS, 0-15 AMPERES |
MIL-HDBK-217 Revision F:1991 | RELIABILITY PREDICTION OF ELECTRONIC EQUIPMENT |
W-F-1814-61 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 250 Volts, 401-600 Amperes |
W-F-1814-9 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Class J (Current-Limiting) 600 Volts, 201-400 Amperes |
W-F-1814-5 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Class J (Current-Limiting) 600 Volts, 0-30 Amperes |
W-F-1814-62 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 600 Volts, 0-30 Amperes |
W-F-1814-57 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Living) 250 Volts, 31-60 Amperes |
W-F-1814-10 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Class J (Current-Limiting) 600 Volts, 401-600 Amperes |
W-F-1814-4 Revision D:2015 | FUSE, CARTRIDGE, HIGH INTERRUPTING CAPACITY, CLASS G (CURRENT-LIMITING) 480 VOLTS, 31-60 AMPERES |
NASA KSC STD E 0001 : 2008 | DESIGN OF ELECTRICAL CONTROL AND MONITORING SYSTEMS, EQUIPMENT (GSE), AND PANELS, STANDARD FOR |
W-F-1814-7 Revision D:2013 | FUSE, CARTRIDGE, HIGH INTERRUPTING CAPACITY, CLASS J (CURRENT-LIMITING) 600 VOLTS, 61-100 AMPERES |
W-F-1814-67 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 600 Volts, 401-600 Amperes |
W-F-1814-60 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 250 Volts, 201-400 Amperes |
W-F-1814-59 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 250 Volts, 101-200 Amperes |
W-F-1814-65 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 600 Volts, 101-200 Amperes |
W-F-1814-8 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Class J (Current-Limiting) 600 Volts, 101-200 Amperes |
W-F-1814-63 Revision E:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 600 Volts, 31-60 Amperes |
W-F-1814-6 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Class J (Current-Limiting) 600 Volts, 31-60 Amperes |
W-F-1814-56 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 250 Volts, 0-30 Amperes |
W-F-1814-64 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 600 Volts, 61-100 Amperes |
W-F-1814-66 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 600 Volts, 201-400 Amperes |
W-F-1814-58 Revision D:2013 | Fuse, Cartridge, High Interrupting Capacity, Classes RK1 and RK5 (Current-Limiting) 250 Volts, 61-100 Amperes |
MIL-STD-202-211 Base Document:2015 | METHOD 211, TERMINAL STRENGTH |
ASTM D 710 : 2013 : REDLINE | Standard Specification for Vulcanized Fibre Sheets, Rods, and Tubes Used for Electrical Insulation |
ANSI/NCSL Z540 3 : 2006(R2013) | REQUIREMENTS FOR THE CALIBRATION OF MEASURING AND TEST EQUIPMENT |
UL 248-8:3ED 2011-05 | Low-Voltage Fuses - Part 8: Class J Fuses |
ASTM B 121/B121M : 2016 : REDLINE | Standard Specification for Leaded Brass Plate, Sheet, Strip, and Rolled Bar |
UL 248-12:3ED 2011-05 | Low-Voltage Fuses - Part 12: Class R Fuses |
ASTM B 152/B152M : 2013 : REDLINE | Standard Specification for Copper Sheet, Strip, Plate, and Rolled Bar |
UL 248-10:3ED 2011-05 | Low-Voltage Fuses - Part 10: Class L Fuses |
UL 248-9:2ED 2000-08 | Standard for Low-Voltage Fuses - Part 9: Class K Fuses |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
UL 248-1 : 3 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS |
A-A-59544 Revision A:2008 | CABLE AND WIRE, ELECTRICAL (POWER, FIXED INSTALLATION) |
MIL-STD-202 Revision H:2015 | ELECTRONIC AND ELECTRICAL COMPONENT PARTS |
UL 248-5:2ED 2000-08 | Standard for Low-Voltage Fuses - Part 5: Class G Fuses |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.