• There are no items in your cart

ASTM D 6196 : 1997

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Practice for Selection of Sorbents and Pumped Sampling/Thermal Desorption Analysis Procedures for Volatile Organic Compunds in Air

Superseded date

11-11-2014

Published date

11-10-1997

1.1 This practice is intended to assist in the selection of sorbents and procedures for the sampling and analysis of ambient (Ref 1), indoor (2) and the workplace (3) atmospheres for a variety of common volatile organic compounds (VOCs). It may also be used for measuring emissions from materials in small or full scale environmental chambers or for human exposure assessment.

1.2 A complete listing of VOCs for which this practice has been tested, at least over part of the measurement range (1.5), is shown in Tables 1-6. For other compounds this practice shall be tested according to EN 1076 or other appropriate validation protocols (Sections 13 and 14). (4,1)

1.3 This practice is based on the sorption of VOCs from air onto selected sorbents for combinations of sorbents. Sampled air is pulled through a tube containing these sorbents. The sorbed VOCs are subsequently recovered by thermal desorption and analyzed by capillary gas chromatography.

1.4 This practice recommends a number of sorbents that can be packed in sorbent tubes, for use in the sampling of a wide range of different volatile organic compounds, in the range 0 to 400°C (v.p. 15 to 0.01 kPa at 25°C). Single-bed tubes containing for example sorbent Type A3,4 are appropriate for normal alkanes from n-C6(hexane) to n-C10(decane) and substances with similar volatility (v.p. 15 to 0.3 kPa at 25°C). More volatile materials should be sampled on stronger sorbents, such as sorbent Type B3,5. Other sorbent types than those specified may be used, if their breakthrough capacities are adequate and their thermal desorption blanks are sufficiently small. Examples are given in Appendix X2. A broader range of VOCs may be sampled using multi-bed tubes

1.5 This practice can be used for the measurement of airborne vapors of these volatile organic compounds in a concentration range of approximately 0.1 ug/m3 to 1g/m3, for individual organic compounds in 1-10 L air samples. The method is also suitable for the measurement of the airborne concentrations of individual components of volatile organic mixtures, provided that the total loading of the mixture does not exceed the capacity of the tube. Quantitative measurements are possible when using validated procedures with appropriate quality assurance measures.

1.5.1 The upper limit of the useful range is set by the sorptive capacity of the sorbent used, and by the linear dynamic range of the gas chromatograph, column and detector, or by the sample splitting capability of the analytical instrumentation used. The sorptive capacity is measured as a breakthrough volume of air, which determines the maximum air volume that must not be exceeded when sampling.

1.5.2 The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte or interfering artifacts, or both, on the sorbent tubes.

1.5.3 Artifacts are typically <1ng for well conditioned sorbent Type C3,6 and carbonaceous sorbents such as graphitized carbon, carbon molecular sieves and pure charcoals; at 1 to 5 ng levels for sorbent Type D3,7 and at 5 to 50 ng levels for Type E3,8. Method sensitivity is typically limited to 0.5 ug/m3 for 10 L air samples with this latter group of sorbent types because of their inherent high background.

1.6 This procedure is compatible with low flow rate personal sampling pumps and can be used for personal and fixed location sampling. It cannot be used to measure instantaneous or short-term fluctuations in concentration. Alternatives for on-site measurement include, but are not limited to gas chromatography and infrared spectrometry.

1.7 The sampling method gives a time-weighted average result.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
D 22
DocumentType
Standard Practice
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM D 8142 : 2017 Standard Test Method for Determining Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation using Micro-Scale Environmental Test Chambers
ASTM D 5116 : 2017 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products
ASTM D 6306 : 2017 Standard Guide for Placement and Use of Diffusive Samplers for Gaseous Pollutants in Indoor Air
ASTM D 7758 : 2017 Standard Practice for Passive Soil Gas Sampling in the Vadose Zone for Source Identification, Spatial Variability Assessment, Monitoring, and Vapor Intrusion Evaluations
ASTM D 7297 : 2014 Standard Practice for Evaluating Residential Indoor Air Quality Concerns
ASTM D 7339 : 2018 Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography
ASTM D 7911 : 2014 Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test
ASTM D 7706 : 2017 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
ASTM D 7648/D7648M : 2018 Standard Practice for Active Soil Gas Sampling for Direct Push or Manual-Driven Hand-Sampling Equipment
ASTM D 7143 : 2017 Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products
ASTM D 3687 : 2007 : R2012 Standard Practice for Analysis of Organic Compound Vapors Collected by the Activated Charcoal Tube Adsorption Method
ASTM D 6803 : 2013 Standard Practice for Testing and Sampling of Volatile Organic Compounds (Including Carbonyl Compounds) Emitted from Paint Using Small Environmental Chambers
ASTM D 1356 : 2017 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 6670 : 2018 Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products
ASTM D 6330 : 1998 : R2014 Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test Conditions
ASTM D 6177 : 2014 Standard Practice for Determining Emission Profiles of Volatile Organic Chemicals Emitted from Bedding Sets
ASTM D 6399 : 2018 Standard Guide for Selecting Instruments and Methods for Measuring Air Quality in Aircraft Cabins
ASTM D 7663 : 2012 : R2018 : EDT 1 Standard Practice for Active Soil Gas Sampling in the Vadose Zone for Vapor Intrusion Evaluations

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.