• There are no items in your cart

BS EN 50411-2-9:2010

Current

Current

The latest, up-to-date edition.

Fibre organisers and closures to be used in optical fibre communications systems. Product specifications Non-sealed closures for air blown fibre microduct cable, for category S & A

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

03-31-2010

1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Description
5 Variants
6 Dimensions
7 Tests
8 Test report
9 Performance requirements
Annex A (informative) - Sample size and product sourcing
        requirements
Annex B (informative) - Closure minimum internal diameters,
        containing microduct connectors
Annex C (informative) - Typical buried subterranean blown
        fibre microduct cable outside diameters
Annex D (informative) - Microduct definitions and sketches
Annex E (informative) - Microduct minimum bend radius
Annex F (informative) - Typical (U) closure configurations

Gives the initial, start of life dimensional, mechanical and environmental performance requirements which a fully installed blown fibre protected, non-sealed closure for duct and microduct cable, must meet in order for it to be categorised as an EN standard product.

1.1 Product definition This specification contains the initial, start of life dimensional, mechanical and environmental performance requirements which a fully installed blown fibre protected, non-sealed closure for duct and microduct cable, must meet in order for it to be categorised as an EN standard product. These products are suitable for installation of and use with microduct fibre units, microduct optical fibre cables, microduct and protected microduct as defined within EN 60794-5. When the non-sealed closures are installed in subterranean environments it is mandatory to use sealed ABF connectors meeting EN 50411-2-8 in order to guarantee the expected network performance and reliability. 1.2 Operating environment The tests selected combined with the severities and duration are representative of an outside plant for subterranean and/or aerial environment defined by: - ETSI EN 300 019 series: Class 8.1: underground locations (without earthquake requirement); - EN 61753-1: Category S: subterranean environment; Category A: aerial environment. 1.3 Test severity The test severities are based on IP40 (see EN 60529). The test criteria for all mechanical and environmental tests cover visual appearance, and protected microduct retention of the closure. It is generally accepted practice that liquids will enter the closure through its body or connected ducts. 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is a minimum of 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme. 1.6 Allowed fibre and cable types This closure standard covers all IEC/EN standard optical fibre microducts, and protected microducts with their various fibre capacities, types and designs. This includes optical fibre cable standard EN 60794-5. This product specification has only considered protected microduct cables containing microducts of same outside diameters. There are other hybrid protected microduct cables with microducts of differing OD’s; it may be possible to use these hybrids, however the user must verify suitability in each case. 1.7 Allowed microduct connector types This closure standard covers all EN standard microduct connectors, including: straight, reducer/enlarger stem, reducer/enlarger, close down, liquid block, liquid block with barb end, and end stop connectors. This includes EN 50411-2-8. 1.8 Microduct storage constraints Microduct excess storage is not required in all air blown fibre closures. Some closure types do not have sufficient internal space to provide storage. The need for microduct storage is provided inside the closure when opened, typically to ensure that there is enough microduct to fulfil the following functions: • remove the coiled microduct attached to the ‘closedown’ connectors, to a remote location, close to blowing equipment, in the process uncoiling the microducts to aid blowing; • provide additional microduct if repeated cut backs for connectors are planned or likely to be fitted throughout the closure life. The minimum microduct storage bend radius is based on the outside diameter and material selection, typically based on 12 times the outside diameter (below 8 mm) and 20 times above. During fibre blowing the bend radius is typically 20 times the microduct diameter.

Committee
GEL/86/2
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Current

Standards Relationship
EN 50411-2-9:2010 Identical

EN 61300-2-5:2011 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion
EN 61300-2-1:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal)
EN 61300-2-10:2012 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - BASIC TEST AND MEASUREMENT PROCEDURES - PART 2-10: TESTS - CRUSH RESISTANCE (IEC 61300-2-10:2012)
IEC 61300-2-37:2016 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-37: Tests - Cable bending for fibre optic closures
EN 61300-2-37:2016 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-37: Tests - Cable bending for fibre optic closures
EN 50411-2-8:2009 Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-8: Microduct connectors, for air blown optical fibres, Type 1
IEC 61300-2-1:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-1: Tests - Vibration (sinusoidal)
IEC 61300-2-12:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact
EN 50411-2-5:2009 Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-5: Sealed closures for air blown fibre microduct, type 1, for category S & A
EN 50411-2:2008 Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2: General and guidance for optical fibre cable joint closures, protected microduct closures, and microduct connectors
EN 61300-2-22:2007 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature
IEC 61753-1:2007 Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards
EN 61753-1:2007 Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards
IEC 61300-2-5:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-5: Tests - Torsion
IEC 61300-2-26:2006 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist
EN 61300-2-33:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures
IEC 60794-5:2014 Optical fibre cables - Part 5: Sectional specification - Microduct cabling for installation by blowing
EN 61300-2-34:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures
ISO 1998-1:1998 Petroleum industry Terminology Part 1: Raw materials and products
IEC 61300-2-22:2007 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature
EN 61300-3-1:2005 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60068-2-10:2005 Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth
EN 61300-2-12:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-12: Tests - Impact
IEC 61300-2-34:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures
EN 61300-2-4:1997 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention
EN 60794-5:2016 Optical fibre cables - Part 5: Sectional specification - Microduct cabling for installation by blowing
IEC 61300-2-33:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-33: Tests - Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures
IEC 61300-2-4:1995 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-4: Tests - Fibre/cable retention
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 61300-2-26:2007 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-26: Tests - Salt mist
IEC 61300-3-1:2005 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination
IEC 61300-2-10:2012 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-10: Tests - Crush resistance

View more information
US$277.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.