NUCLEAR ENERGY - MEASUREMENT OF RADIOACTIVITY IN THE ENVIRONMENT - AIR - RADON 222: METHODS FOR INTEGRATED MEASUREMENT OF THE AVERAGE VOLUMIC ACTIVITY OF RADON IN THE ATMOSPHERIC ENVIRONMENT, WITH A PASSIVE COLLECTION AND AN DEFERRED ANALYSIS

Superseded date

10-01-2012

Published date

01-12-2013

Avant-propos
1 Domaine d'application
2 Références normatives
3 Termes et définitions
4 Principe de la mesure
5 Prélèvement
  5.1 But du prélèvement
  5.2 Caractéristiques du prélèvement
  5.3 Conditions de prélèvement
6 Mesure de la grandeur physique accumulée
  6.1 But de la mesure
  6.2 Principe de la mesure
7 Grandeurs d'influence
8 Étalonnage
9 Expression des résultats
Annexe A (informative) Exemple de fiche d'expression des
                       résultats mesure intégrée de
                       l'activité volumique moyenne du radon
                       222 (NF M 60-766)
Annexe B (informative) Exemples de méthodes pouvant répondre
                       aux exigences du présent document
Bibliographie

Il existe de nombreuses méthodes pour mesurer l'activité volumique du radon 222 dans l'atmosphère (méthodes de mesure ponctuelle, en continu, intégrée, avec un prélèvement d'air actif ou passif). Le présent document concerne uniquement les techniques de mesure intégrée du radon 222, utilisant un prélèvement passif. Il donne des indications pour mesurer l'activité volumique moyenne du radon 222 dans une atmosphère libre (extérieur) ou confinée (bâtiments), à partir d'un prélèvement passif de mise en oeuvre facile et de faible coût, et donne les conditions d'utilisation des dispositifs de mesure. Ce document concerne des prélèvements effectués sur des durées de quelques semaines à une année. Tout système dont la durée d'exposition ne peut excéder la semaine n'est pas traité dans le présent document.

DevelopmentNote
Indice de classement: M60-766. PR NFM 60 766 January 2004. (01/2004)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

BS IEC 61577-1:2006 Radiation protection instrumentation. Radon and radon decay product measuring instruments General principles
BS ISO 18589-1:2005 Measurement of radioactivity in the environment. Soil General guidelines and definitions
ISO 18589-1:2005 Measurement of radioactivity in the environment Soil Part 1: General guidelines and definitions
NFM 60 772 : 2012 ENERGIE NUCLEAIRE - MESURE DE LA RADIOACTIVITE DANS L'ENVIRONNEMENT - AIR - LE RADON 222 DANS LES CAVITES ET OUVRAGES SOUTERRAINS: METHODOLOGIE APPLIQUEE AU DEPISTAGE
04/30078214 DC : DRAFT AUG 2004 IEC 61577-1 - RADIATION PROTECTION INSTRUMENTATION - RADON AND RADON DECAY PRODUCT MEASURING INSTRUMENTS - PART 1: GENERAL PRINCIPLES
NFM 60 771 : 2011 NUCLEAR ENERGY - MEASUREMENT OF ENVIRONMENTAL RADIOACTIVITY - AIR - RADON 222 IN THE BUILDINGS: METHODOLOGIES APPLIES FOR THE SCREENING AND FOR THE COMPLEMENTARY INVESTIGATIONS
IEC 61577-1:2006 Radiation protection instrumentation - Radon and radon decay product measuring instruments - Part 1: General principles
NFM 60 763 : 2004 NUCLEAR ENERGY - MEASUREMENT OF RADIOACTIVITY IN THE ENVIRONMENT - AIR - RADON 222 AND ITS SHORT-LIFE DECAY PRODUCTS IN THE ATMOSPHERIC ENVIRONMENT: THEIR ORIGINS AND MEASURING METHODS

IEC 61577-1:2006 Radiation protection instrumentation - Radon and radon decay product measuring instruments - Part 1: General principles
NFM 60 771 : 2011 NUCLEAR ENERGY - MEASUREMENT OF ENVIRONMENTAL RADIOACTIVITY - AIR - RADON 222 IN THE BUILDINGS: METHODOLOGIES APPLIES FOR THE SCREENING AND FOR THE COMPLEMENTARY INVESTIGATIONS
ISO 11929-1:2000 Determination of the detection limit and decision threshold for ionizing radiation measurements Part 1: Fundamentals and application to counting measurements without the influence of sample treatment
NF ENV 13005 : 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
IEC 61577-2:2014 Radiation protection instrumentation - Radon and radon decay product measuring instruments - Part 2: Specific requirements for <sup>222</sup>Rn and <sup>220</sup>Rn measuring instruments
ISO 921:1997 Nuclear energy Vocabulary
NFM 60 763 : 2004 NUCLEAR ENERGY - MEASUREMENT OF RADIOACTIVITY IN THE ENVIRONMENT - AIR - RADON 222 AND ITS SHORT-LIFE DECAY PRODUCTS IN THE ATMOSPHERIC ENVIRONMENT: THEIR ORIGINS AND MEASURING METHODS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.