• There are no items in your cart

SN EN 60444-3 : 1997

Current

Current

The latest, up-to-date edition.

MEASUREMENT OF QUARTZ CRYSTAL UNIT PARAMETERS BY ZERO PHASE TECHNIQUE IN A PI-NETWORK - PART 3: BASIC METHOD FOR THE MEASUREMENT OF TWO-TERMINAL PARAMETERS OF QUARTZ CRYSTAL UNITS UP TO 200 MHZ BY PHASE TECHNIQUE IN A PI-NETWORK WITH COMPENSATION OF THE PARALLEL CAPACITANCE C<(INDEX)O>

Published date

01-12-2013

Committees responsible
National foreword
Method
1 Scope
2 Co compensation circuit
    2.1 Electrical specifications
    2.2 Mechanical specification
3 Crystal unit parameters with and without Co
    compensation
    3.1 Series resonance frequency fs and resonance
          frequency fr
    3.2 Motional resistance Rl and resonance resistance
          Rr
    3.3 Motional capacitance Cl and motional inductance
          Ll
4 Test circuit
    4.1 The pi-network
    4.2 Accessories of the pi-network
    4.3 Associated equipment
    4.4 Compensation circuit
5 Method of measurement
    5.1 Initial calibration of the pi-network
    5.2 Tuning of the compensation circuit
    5.3 Frequency and resistance measurement
    5.4 Evaluation of the motional capitance Cl and
          motional inductance Ll
Appendices
A Analysis of the difference of f, R, Cl and Ll as result
    of measurement methods with and without compensation of Co
B Additional information on accuracy
C Additional information on circuit components given in
    Figures 4a) and 4b)
Table
A1 Typical values for parameters of oscillator crystal units
    and the calculated theoretical differences between
    parameters increased with and without compensation
Figures
1 Equivalent circuit of a crystal unit with compensation
    of Co
2 Impedance diagram of a crystal unit without compensation
    of parallel capacitance Co
3 Impedance diagram of a crystal unit when Co is
    compensated with a properly tuned compensation network
    according to Figure 1
4a Simplified diagram of the pi-network with electrical
    adjustment of Co compensation
4b Simplified diagram of the pi-network with mechanical
    adjustment of Co compensation
5 Test circuit

Defines a method for measuring the parameters of quartz crystal units by means of an inductance for compensation for the effects of Co at the frequency of the crystal unit, with accuracy dependent on the type of crystals for frequency with a fractional accuracy ranging between 10-6 and 10-8, 2% and 5% and motional capacitance and inductance with a fractional accuracy between 3% and 7%.

DocumentType
Standard
PublisherName
Swiss Standards
Status
Current

Standards Relationship
BS EN 60444-3:1997 Identical
EN 60444-3:1997 Identical
I.S. EN 60444-3:1999 Identical
DIN EN 60444-3:1997-10 Identical

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.