AS 3200.2.20-1992

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Approval and test specification - Medical electrical equipment Particular requirements for safety - Baby incubators (transport)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

30-06-2017

Published date

01-01-1992

Preview

1 - AS 3200.2.20-1992 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY-BABY INCUBATORS (TRANSPORT)
4 - PREFACE
5 - CONTENTS
7 - SECTION ONE-GENERAL
7 - 1. Scope and object
8 - 2. Terminology and definitions
9 - 3. General requirements
9 - 4. General requirements for tests
10 - 5. Classification
10 - 6. Identification, marking and documents
12 - 7. Power input
13 - SECTION TWO-ENVIRONMENTAL CONDITIONS
13 - 10. Environmental conditions
13 - SECTION THREE-PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
13 - 20. Dielectric strength
13 - SECTION FOUR-PROTECTION AGAINST MECHANICAL HAZARDS
13 - 21. Mechanical strength
14 - 22. Moving parts
14 - 23. Surfaces, corners and edges
15 - 24. Stability in NORMAL USE
16 - SECTION FIVE-PROTECTION AGAINST HAZARDS FROM UNWANTED OR EXCESSIVE RADIATION
16 - 36. Electromagnetic compatibility
16 - SECTION SIX-PROTECTION AGAINST HAZARDS OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES
17 - SECTION SEVEN-PROTECTION AGAINST EXCESSIVE TEMPERATURES, AND OTHER SAFETY HAZARDS
17 - 42. Excessive temperatures
17 - 43. * Fire prevention
18 - 44. Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization and disinfection
19 - 45. Pressure vessels and parts subject to PRESSURE
19 - 46. Human errors
20 - 49. Interruption of the power supply
20 - SECTION EIGHT-ACCURACY OF OPERATING DATA AND PROTECTION AGAINST HAZARDOUS OUTPUT
20 - 50. Accuracy of operating data
23 - 51. Protection against hazardous output
23 - SECTION NINE-ABNORMAL OPERATION AND FAULT CONDITIONS; ENVIRONMENTAL TESTS
23 - SECTION TEN-CONSTRUCTIONAL REQUIREMENTS
23 - 54. General
24 - 55. ENCLOSURES and covers
24 - 56. Components and general assembly
25 - SECTION ELEVEN-ADDITIONAL REQUIREMENTS
25 - 101. Alarms
27 - 102. Sound pressure level
27 - 103. * Humidifying unit
27 - 104. * Maximum air velocity in the enclosure
27 - 105. * Concentration of carbon dioxide (CO2 )
28 - 106. Provision of oxygen
28 - 107. Electrical power supply
32 - Annexes
32 - Appendix L - References - Publications mentioned in this standard
33 - Annex AA - General guidance and rationale
38 - APPENDIX LL - REFERENCES-PUBLICATIONS MENTIONED IN THIS STANDARD
38 - APPENDIX TT - TOLERANCES FOR APPLICATION IN AUSTRALIA
39 - APPENDIX ZZ - AMENDMENTS TO IEC 601-2-20 FOR APPLICATION IN AUSTRALIA

Specifies requirements for transport incubators suitable for the safe conveyance of a baby outside a normal clinical baby-care environment. This Standard does not apply to transport incubators in which heating is provided by means of radiant heat sources. This Standard is to be read in conjunction with AS 3200.1.0-1990, and is technically equivalent to IEC 601-2-20:1990.

Addition:This Particular Standard specifies safety requirements for TRANSPORT INCUBATORS, as defined in 2.1.101 of this standard.This standard does not apply to BABY INCUBATORS (see IEC 601-2-19).

Committee
HE-003
DocumentType
Standard
ISBN
0 7262 7793 2
Pages
34
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

Standards Relationship
IEC 60601-2-20:1990 Identical

Amendment 1 to AS 3200.2.20-1992 see DR 98481 First published as part of AS 3201.2-1971Ap.Revised and redesignated in part as AS 3200.2.20-1992. First published as part of AS 3201.2-1971Ap. Revised and redesignated in part as AS 3200.2.20-1992.

AS 1259.1-1990 Acoustics - Sound level meters Non-integrating
AS 3200.2.19-1992 Approval and test specification - Medical electrical equipment Particular requirements for safety - Baby incubators (nursing)
AS/NZS 3200.1.0-1998 Medical electrical equipment General requirements for safety - Parent Standard
AS 3200.1.0-1990 Approval and test specification - Medical electrical equipment General requirements for safety - Parent Standard

AS 3200.2.19-1992 Approval and test specification - Medical electrical equipment Particular requirements for safety - Baby incubators (nursing)

View more information
$113.50
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more