DEFSTAN 00-101(PT3)/2(2008) : 2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 3: ELECTRICAL EQUIPMENT AND INSTALLATION
Hardcopy , PDF
28-11-2020
English
01-01-2008
0. INTRODUCTION
1. SCOPE
2. WARNING
3. RELATED DOCUMENTS
4. DEFINITIONS AND ABBREVIATIONS
5. AMENDMENT
6. SPONSORSHIP OF THE REQUIREMENT AND SECURITY
7. STATUTORY LEGISLATION AND MOD REGULATION FOR PLATFORM
EXPLOSIVE SAFETY
8. INTRODUCTION TO PLATFORM EXPLOSIVES SAFETY AND CERTIFICATION
9. DESIGN FOR PLATFORM EXPLOSIVES SAFETY INCORPORATING
THREAT HAZARD ASSESSMENT & LINES OF DEFENCE
APPENDIX 1 - DESIGN REQUIREMENTS FOR ELECTRICAL EQUIPMENT
IN MAGAZINES, WSCs AND DESIGNATED DANGER AREAS
1.1 Description
1.2 Performance Requirements - Categorisation of Magazines
1.3 Performance Requirements - Basic Principles for
Magazine Electrical Equipment
1.4 Performance Requirements - Basic Principles - Zone 2
Magazines
1.5 ACOP - Basic Principles - Zone 2 Magazines
1.6 ACOP - Zone 2 Magazine Electrical Equipment Categories
1.7 Performance Requirement - Assessment of Equipment for
use in Zone 2
1.8 ACOP - Electrical Equipment Enclosures
1.9 ACOP - The Radio Frequency (rf) Environment
1.10 ACOP - Magnetic Environment and Degaussing Cables
1.11 Guidance - Basic Principles for Magazine, WSC & DDA
Electrical Equipment
1.12 Guidance - Basic Principles for Zone 2 Magazine,
WSC & DDA Electrical Equipment
1.13 Guidance on Maximum Surface Temperature
1.14 Guidance on Electrical Equipment Enclosures
1.15 Guidance on Intrinsically Safe Equipment
1.16 Guidance on Mobile Mechanical Handling Equipment (MMHE)
1.17 Guidance on Mechanical Hazards
1.18 Guidance on Safety and Environmental Management Systems
(SEMS)
APPENDIX 2 - DESIGN REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
2.1 Description
2.2 Performance Requirements for General Installation
and Siting
2.3 Performance Requirements for Cabling
2.4 Performance Requirements for Circuit Isolation
2.5 Performance Requirements for Emergency Supplies
2.6 Performance Requirements for Fixed Lighting
2.7 Performance Requirements for Power Output Connectors
2.8 Performance Requirements for Installed Test Equipment
2.9 Performance Requirements for Electrically Controlled
Handling Machinery
2.10 Performance Requirements for Safety-Related Devices
2.11 Performance Requirements for Earthing
2.12 ACOP for Siting of Equipment
2.13 ACOP for Cabling
2.14 ACOP for Circuit Isolation
2.15 ACOP for Emergency Supplies
2.16 ACOP for Luminaries (Fixed Lighting)
2.17 ACOP for Power Output Connectors
2.18 ACOP for Test Equipment
2.19 ACOP for Electrically Controlled Handling Machinery
2.20 ACOP for Safety-Related Devices
2.21 ACOP for Earthing
2.22 Guidance on General Electrical Installation
2.23 Guidance on Siting of Equipment
2.24 Guidance on Cabling
2.25 Guidance on Circuit Isolation
2.26 Guidance on Fixed Lighting
2.27 Guidance on Power Output Connectors
2.28 Guidance on Test Equipment
2.29 Guidance on Electrically Controlled Handling Machinery
APPENDIX 3 - DESIGN REQUIREMENTS FOR ADJACENT COMPARTMENTS
3.1 Description
3.2 Performance Requirements for Electrical Design in
Adjacent Compartments
3.3 Performance Requirements for Electrical Equipment
in Adjacent Compartments
3.4 Performance Requirements for Electrical Installation
in Adjacent Compartments
3.5 Performance Requirements for Smoke/Heat Detection
Equipment in Adjacent Compartments
3.6 ACOP for Special Requirements in Adjacent Compartments
3.7 ACOP for Special Requirements for Installation in
Adjacent Compartments
3.8 ACOP for Smoke and Heat Detection Equipment
3.9 Guidance on Electrical Equipment in Adjacent Compartments
APPENDIX 4 - DESIGN REQUIREMENTS FOR TEMPORARILY INSTALLED EQUIPMENT
4.1 Description
4.2 Performance Requirements for Portable Equipment
4.3 Performance Requirements for Emergency Lighting
4.4 ACOP for Temporarily Installed Equipment
4.5 Guidance on Temporarily Installed Equipment
4.6 Guidance on Compliance for Portable Equipment
APPENDIX 5 - ELECTROMAGNETIC INDUCTION, RADIO FREQUENCY AND
ELECTROSTATIC HAZARDS
5.1 Description
5.2 Performance Requirements for Design to Reduce
Electromagnetic Induction, Radio Frequency and
Electrostatic Hazards
5.3 ACOP for Electromagnetic Induction, Radiation and
Electrostatic Hazards
5.4 Guidance on Electromagnetic Induction, Radiation and
Electrostatic Hazards
APPENDIX 6 - POTENTIALLY HAZARDOUS ENVIRONMENTS OF A SPECIAL
NATURE
6.1 Description
6.2 Performance Requirements for Potentially Hazardous
Environments of a Special Nature
6.3 Performance Requirements for Degaussing Cables
6.4 Performance Requirements for Waveguides
6.5 Performance Requirements for Cranes
6.6 Performance Requirements for Ship to Shore Electrical
Connections
6.7 ACOP for Waveguides
6.8 ACOP for Cranes
6.9 ACOP for Ship to Shore Electrical Connections
6.10 ACOP for Earthing of Weapon Containers
6.11 Guidance on Degaussing Cables
6.12 Guidance on Waveguides
6.13 Guidance on Ship to Shore Connections
APPENDIX 7 - Electrical Requirements for ISO Containers
7.1 Description
7.2 ACOP for Earthing of ISO Containers
7.3 Guidance on Earthing of ISO Containers
ANNEX A - RELATED DOCUMENTS
ANNEX B - ABBREVIATIONS
ANNEX C - DEFINITIONS
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.