UNI EN 13786 : 2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
AUTOMATIC CHANGE-OVER VALVES HAVING A MAXIMUM OUTLET PRESSURE OF UP TO AND INCLUDING 4 BAR WITH A CAPACITY OF UP TO AND INCLUDING 100 KG/H, AND THEIR ASSOCIATED SAFETY DEVICES FOR BUTANE, PROPANE OR THEIR MIXTURES
04-07-2013
01-01-2009
Foreword
1 Scope
2 Normative references
3 Terms and definitions
3.1 General terms and definitions
3.2 Terms and definitions concerning gas
3.3 Terms and definitions concerning pressures
3.4 Terms and definitions concerning rates
4 Types of automatic change over devices
4.1 Introduction
4.2 Automatic change over devices for installations
where the final regulator supplies a pressure
specified in EN 437
4.3 Other automatic change over devices installation
5 Constructional characteristics
5.1 General
5.2 Materials
5.3 Special requirements
5.3.1 Pressure sensing subassembly
5.3.2 Regulation subassembly
5.3.3 Back pressure subassembly
5.3.4 Connection subassembly
5.3.5 Supply-reserve indicator
5.3.6 Knob for selection of the operational
cylinder
5.3.7 Fixing onto a wall
5.3.8 Non return valves
5.4 Mechanical strength
5.4.1 Resistance to pressure
5.4.2 Strength of connections
5.5 Soundness
5.6 Mechanical endurance
5.7 Resistance to humidity changes
5.8 Resistance to corrosion
6 Performance characteristics
6.1 General
6.1.1 Introduction
6.1.2 Supply pressure
6.2 Operational limit characteristics (regulation
function)
6.3 Operational limit characteristics (Change over
function)
6.3.1 Change over pressure
6.3.2 Selection of the operating cylinder
7 Test methods
7.1 General conditions
7.1.1 Type of test gas
7.1.2 Test conditions
7.1.3 Equivalence formulae
7.1.4 Test samples
7.2 Verification of constructional characteristics
7.2.1 Resistance to pressure
7.2.2 Mechanical strength of connections
7.2.3 Regulation subassembly
7.2.4 Soundness
7.2.5 Endurance
7.2.6 Resistance to humidity changes
7.2.7 Resistance to corrosion
7.3 Verification of performance characteristics
7.3.1 General
7.3.2 Plotting of regulation curves
8 Marking, packaging, instructions
8.1 General
8.2 Marking of the device
8.3 Packaging
8.4 Instructions for use and maintenance
Annex A (normative) - Special requirements for automatic
change over devices fitted with pressure or rate
operated safety valves
A.1 Change over devices fitted with an over-pressure
relief
A.1.1 Definition
A.1.2 Constructional characteristics
A.1.3 Performance characteristics
A.1.4 Test methods
A.1.5 Automatic change over device marking
A.2 Automatic change over device fitted with
an over-pressure shut off safety valve
A.2.1 Definition
A.2.2 Constructional characteristics
A.2.3 Performance characteristics
A.2.4 Test methods
A.3 Automatic change over device fitted with
an under-pressure shut off safety device
A.3.1 Definition
A.3.2 Constructional and performance
characteristics
A.3.3 Test methods
A.4 Automatic change over devices fitted with
an excess flow valve
A.4.1 Definition
A.4.2 Performance characteristics
A.4.3 Complementary tests for the automatic
change over devices - Test methods
A.4.4 User and maintenance instructions
A.5 Automatic change over devices fitted with
a regulated pressure limiter
A.5.1 Definition
A.5.2 Constructional and performance
characteristics
A.5.3 Test methods
A.5.4 Users and maintenance instructions
Annex B (normative) - Special requirements for automatic
change over devices and automatic change over
device systems for caravans, motor caravans or
fresh water boats
Annex C (normative) - Special requirements for low
pressure automatic change over devices under
extreme temperature conditions (temperatures
below - 20 degrees C)
Annex D (normative) - Method for measuring leaks at
test pressures less than or equal to 16 bar
D.1 Scope
D.2 Diagram of the test bench
D.3 Coefficient K
D.3.1 Method
D.3.2 Calculations
D.4 Measurement of the leak
D.4.1 Method
D.4.2 Calculations
D.5 Checks
Annex E (normative) - Complementary test requirements
for non metallic thermoplastic or thermal setting
materials used in the construction of automatic
change over devices
E.1 Scope
E.2 Materials
E.3 Special conditions for carrying out the test
mentioned in the body of the standard
E.3.1 Resistance to impact
E.3.2 Mechanical resistance of connections
E.3.3 Soundness
E.4 Special requirements
E.4.1 Resistance to hydrocarbons
E.4.2 Resistance to cracking under stress
and when chemical agents are present
E.4.3 Characteristics relating to fire
resistance
E.4.4 Accelerated ageing
E.5 Sampling and order of tests
Annex F (normative) - Requirements for elastomeric
reinforced diaphragms
Annex G (normative) - Inlet connections
Annex H (normative) - Outlet connections
Annex I (normative) - Test method for resistance
to corrosion
I.1 Principle
I.2 Reagents
I.2.1 Saline solution
I.2.2 Compressed air
I.2.3 Salt mist
I.3 Apparatus
I.3.1 Spraying chamber
I.3.2 Sprayers
I.3.3 Heating device
I.3.4 Salt solution supply device
I.3.5 Compressed air supply device
I.3.6 Mist collectors
I.4 Test method
I.4.1 Method of exposure of automatic
change over device
I.4.2 Duration of tests
I.4.3 Checks
I.4.4 Cleaning of automatic change over device
I.5 Results
Annex J (normative) - Automatic change over device and
change over device systems for LPG cylinders
to supply appliances installed in seawater boats
J.1 Scope
J.2 General
J.3 Maximum guaranteed rate
J.4 Change over device and change over device
systems fitted with a pressure relief valve
J.5 Vent
J.6 Connections
J.7 Material
J.8 Resistance to corrosion
J.8.1 General
J.8.2 Requirement
J.8.3 Test method
J.9 Marking
J.10 Instructions for use and maintenance
Annex ZA (informative) - Clauses of this European
Standard addressing essential requirements
or other provisions of EU Directives
Bibliography
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.