UNI EN 15287-2 : 2008
Current
The latest, up-to-date edition.
CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 2: CHIMNEYS FOR ROOM-SEALED APPLIANCES
04-09-2008
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Design
4.1 General
4.2 Data requirements
4.2.1 Sources of data and information
4.2.2 Heating appliance information
4.2.3 Chimney system product specification
4.2.4 Building construction and chimney system
route information
4.2.5 Local conditions
4.3 Design requirements
4.3.1 General
4.3.2 Chimney system designation
4.3.3 Properties of construction of the chimney
4.3.4 Chimney system sizing and characteristics
for room-sealed applications
4.3.5 Chimney system route
4.3.6 Connecting flue pipe and connection air supply
pipe route
4.3.7 Resistance to fire (external to external)
4.3.8 Distance to combustible material (Resistance
to fire internal to external)
4.3.9 Accidental human contact
4.3.10 Accidental ignition of extraneous loose material
4.3.11 Supports
4.3.12 Joints
4.3.13 Chimney offset
4.3.14 Access for inspection, cleaning and measuring
4.3.15 Distance between openings in the chimney system
4.3.16 Back ventilation
4.3.17 Location of chimney outlet
4.3.18 External parts
4.3.19 Weatherproofing
4.3.20 Lightning protection
4.3.21 Earthing of chimney systems
4.3.22 Silencer
4.3.23 Condensate drainage system
4.3.24 Rain cap
4.3.25 Rainwater disposal
4.3.26 Terminals
4.4 Chimney plate and additional information
5 Installation
5.1 General
5.2 Construction of relined or converted chimney systems
5.3 Chimney plate
6 Commissioning/handover
Annex A (normative) - Determination of the chimney and
connecting flue pipe system designation and essential
additional information for custom built, relined and
converted chimney systems, for concentric flue/air
supply duct configuration
A.1 General
A.2 Temperature class
A.3 Pressure class
A.4 Resistance to condensate class
A.5 Corrosion resistance class
A.6 Sootfire resistance class
A.7 Distance to combustible material
A.8 Thermal resistance of the flue duct
A.9 Coefficient of flow resistance of the flue duct
A.10 Thermal resistance of the air supply duct
A.11 Coefficient of flow resistance of the air
supply duct
Annex B (informative) - Information for the heating
appliance(s)
Annex C (informative) - Example of system chimney product
designation
Annex D (informative) - Correlation between designation
parameters for clay/ceramic flue liners and
clay/ceramic flue blocks and concrete flue blocks
Annex E (informative) - Designation of metal system chimneys
and correlation between metal liner material
designation and corrosion load in Member States (MS)
Annex F (informative) - Example of chimney system designation
for room-sealed applications
Annex G (informative) - Example for chimney system plate
G.1 Example of a concentric chimney system configuration
plate
G.2 Example of a separate chimney system configuration
plate
Annex H (normative) - Determination of the chimney designation
for a completed metal system chimney
H.1 General
H.2 Corrosion resistance class
Annex I (informative) - Example of the determination of the
designation of a converted/relined chimney system
I.1 Input data for a typical converted/relined chimney
I.1.1 Existing chimney
I.1.2 Liner
I.1.3 Insulation
I.2 Temperature class designation
I.2.1 General
I.2.2 Material characteristic
I.2.3 Fire protection
I.2.4 Human contact
I.2.5 Determination of temperature class
I.2.6 Check of mean temperatures
I.3 Pressure class designation
I.4 Resistance to condensate class designation
I.5 Corrosion resistance class designation
I.6 Sootfire resistance class
I.7 Distance to combustible material
I.8 Designation of the converted/relined chimney
I.9 Chimney plate of the converted/relined chimney
in this annex
Annex J (informative) - Example for the determination of
the designation of a custom built chimney system
J.1 Input data for a custom-built chimney system
J.1.1 Liner
J.1.2 Insulation
J.1.3 Air supply duct
J.1.4 Combustible wall
J.2 Temperature class designation
J.2.1 General
J.2.2 Material characteristic
J.2.3 Resistance to fire
J.2.4 Human contact
J.2.5 Determination of temperature class
J.2.6 Check of mean temperatures
J.3 Pressure class designation
J.4 Resistance to condensate class designation
J.5 Corrosion resistance class designation
J.6 Sootfire resistance class
J.7 Distance to combustible material
J.8 Designation of the custom-built chimney
J.9 Chimney plate for the custom-built chimney
in this annex
Annex K (informative) - Location of outlets of chimney systems
Annex L (informative) - Method for calculating the temperature
of adjacent materials
L.1 Method for the calculation of the temperature of
adjacent materials
L.2 Example for calculation of the temperature of
adjacent materials
Annex M (informative) - Checking, handling and site storage
of materials and components
M.1 General
M.2 Checking, handling and site storage of materials
and components
M.2.1 Checking on delivery of materials
M.2.2 Checking before installation
M.2.3 Check of existing chimney
M.2.4 Site handling and storage
M.2.5 Coordination of work
Annex N (informative) - Chimney commissioning
N.1 General
N.2 Physical checks
N.3 Operational checks
N.3.1 Flue flow test
N.3.2 Smoke test
N.3.3 Gas tightness test
Method B: O[2] measurement in concentric air supply
ducts for gas
Annex O (informative) - Recommendations for inspection,
cleaning and maintenance
O.1 General
O.2 Inspection and cleaning
O.3 Maintenance
Bibliography