• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 15911:2010

Current

Current

The latest, up-to-date edition.

Foodstuffs - Simultaneous determination of nine sweeteners by high performance liquid chromatography and evaporative light scattering detection

Published date

20-10-2010

Foreword
1 Scope
2 Normative references
3 Principle
4 Reagents
5 Apparatus and equipment
6 Procedure
7 Calculation of results
8 Precision
9 Test report
Annex A (informative) - Table A.1 - Suitable method conditions
Annex B (informative) - Examples of chromatograms
Annex C (informative) - Precision data
Annex D (informative) - Present EU limits for the nine sweeteners
Bibliography

This European Standard specifies a method for the simultaneous determination of nine sweeteners in beverages and canned or bottled fruits by high performance liquid chromatography (HPLC) with evaporative light scattering detection (HPLC-ELSD). This method has been validated in an interlaboratory study via the analysis of spiked samples on the following matrices:-acesulfame-K (ACS-K) (from 38,3 mg/l to 383,5 mg/l) in beverages and (from 38,4 mg/kg to 391,3 mg/kg) in canned fruits;-alitame (ALI) (from 31,1 mg/l to 114,5 mg/l) in beverages and (from 36 mg/kg to 175,2 mg/kg) in canned fruits;-aspartame (ASP) (from 38,1 mg/l to 702 mg/l) in beverages and (from 37,2 mg/kg to 1 120,2 mg/kg) in canned fruits;-cyclamic acid (CYC) (from 28,3 mg/l to 307,2 mg/l) in beverages and (from 27,5 mg/kg to 1 100,6 mg/kg) in canned fruits;-dulcin (DUL) (from 55,0 mg/l to 115,1 mg/l) in beverages and (from 49,8 mg/kg to 172,6 mg/kg) in canned fruits;-neotame (NEO) (from 37,6 mg/l to 115,3 mg/l) in beverages and (from 37,3 mg/kg to 173,7 mg/kg) in canned fruits;-neohesperidine dihydrochalcone (NHDC) (from 31,4 mg/l to 59,3 mg/l) in beverages and (from 35,3 mg/kg to 59,3 mg/kg) in canned fruits;-saccharin (SAC) (from 36,2 mg/l to 87,6 mg/l) in beverages and (from 44,3 mg/kg to 235,3 mg/kg) in canned fruits;-sucralose (SCL) (from 36,8 mg/l to 346,8 mg/l) in beverages and (from 35,3 mg/kg to 462,4 mg/kg) in canned fruits.For further information on the validation results see Annex C.NOTEThe method has been fully validated [1] through collaborative trial, according to the IUPAC Harmonised Protocol [2], on analyte-matrix combinations of all nine sweeteners in beverages and canned or bottled fruits.

Committee
CEN/TC 275
DevelopmentNote
Supersedes PREN 15911. (04/2011)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
DIN EN 15911:2011-01 Identical
NS EN 15911 : 2010 Identical
PN EN 15911 : 2010 Identical
UNI EN 15911 : 2010 Identical
UNE-EN 15911:2011 Identical
NF EN 15911 : 2010 Identical
I.S. EN 15911:2010 Identical
SN EN 15911 : 2011 Identical
DIN EN 15911 E : 2011 Identical
BS EN 15911:2010 Identical
NBN EN 15911 : 2010 Identical
NEN EN 15911 : 2010 Identical

ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
EN ISO 3696:1995 Water for analytical laboratory use - Specification and test methods (ISO 3696:1987)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.