COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
Amendment of

EN 60694:1996

Superseded date

05-12-2008

Published date

18-09-2001

FOREWORD
1 General
   1.1 Scope
   1.2 Normative references
2 Normal and special service conditions
   2.1 Normal service conditions
   2.2 Special service conditions
3 Definitions
   3.1 General terms
   3.2 Assemblies of switchgear and controlgear
   3.3 Parts of assemblies
   3.4 Switching devices
   3.5 Parts of switchgear and controlgear
   3.6 Operation
   3.7 Characteristic quantities
   3.8 Index of definitions
4 Ratings
   4.1 Rated voltages (U[r])
   4.2 Rated insulation level
   4.3 Rated frequency (f[r])
   4.4 Rated normal current and temperature rise
   4.5 Rated short-time withstand current (l[k])
   4.6 Rated peak withstand current (l[p])
   4.7 Rated duration of short circuit (t[k])
   4.8 Rated supply frequency of closing and opening
        devices and of auxiliary circuits (U[a])
   4.9 Rated supply frequency of closing and opening
        devices and of auxiliary circuits
   4.10 Rated pressure of compressed gas supply for
        insulation and/or operation
5 Design and construction
   5.1 Requirements for liquids in switchgear and
        controlgear
   5.2 Requirements for gases in switchgear and
        controlgear
   5.3 Earthing of switchgear and controlgear
   5.4 Auxiliary and control equipment
   5.5 Dependent power operation
   5.6 Stored energy operation
   5.7 Independent manual operation
   5.8 Operation of releases
   5.9 Low- and high-pressure interlocking and
        monitoring devices
   5.10 Nameplates
   5.11 Interlocking devices
   5.12 Position indication
   5.13 Degrees of protection by enclosures
   5.14 Creepage distances
   5.15 Gas and vacuum tightness
   5.16 Liquid tightness
   5.17 Flammability
   5.18 Electromagnetic compatibility (EMC)
6 Type tests
   6.1 General
   6.2 Dielectric tests
   6.3 Radio interference voltage (r.i.v.) test
   6.4 Measurement of the resistance of circuits
   6.5 Temperature-rise tests
   6.6 Short-time withstand current and peak withstand
        current tests
   6.7 Verification of the protection
   6.8 Tightness tests
   6.9 Electromagnetic compatibility tests (EMC)
7 Routine tests
   7.1 Dielectric test on the main circuit
   7.2 Dielectric test on auxiliary and control circuits
   7.3 Measurement of the resistance of the main
        circuit
   7.4 Tightness test
   7.5 Design and visual checks
8 Guide to the selection of switchgear and controlgear
9 Information to be given with enquiries, tenders and
   orders
10 Rules for transport, storage, installation, operation
   and maintenance
   10.1 Conditions during transport, storage and
         installation
   10.2 Installation
   10.3 Operation
   10.4 Maintenance
11 Safety
   11.1 Electrical aspects
   11.2 Mechanical aspects
   11.3 Thermal aspects
   11.4 Operation aspects
Annexes
A (normative) Identification of test specimens
B (normative) Determination of the equivalent r.m.s. value
                 of a short-time current during a short
                 circuit of a given duration
C (normative) Method for the weatherproofing test for outdoor
                 switchgear and controlgear
D (informative) Information about insulation levels and tests
E (informative) Tightness (information, example and guidance)
F (informative) Dielectric testing of self-protected
                 switchgear and controlgear
G (informative) Bibliography
ZA (normative) Normative references to international
                 publications with their corresponding
                 European publications
ZB (normative) Special national conditions

Applicable to a.c. switchgear and controlgear, intended for indoor and outdoor installation, to be operated at service frequencies not exceeding 60 Hz on systems with voltages over 1000 V. Relevant to all high-voltage switchgear and controlgear except as otherwise specified in relevant IEC standards for a particular type of switchgear and controlgear.

Committee
TC 17AC
DevelopmentNote
Supersedes HD 448 (05/2001)
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy
Supersedes

BS EN 50123-7-3:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating voltage transducers and other voltage measuring devices
BS EN 62271-2:2003 High-voltage switchgear and controlgear Seismic qualification for rated voltages of 72,5 kV and above
BS EN 60077-4:2003 Railway applications. Electric equipment for rolling stock Electrotechnical components. Rules for AC circuit-breakers
DIN EN 45510-2-7:2003-12 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
I.S. EN 60044-8:2002 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS
BS EN 60204-11 : 2001 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
BS EN 50123-7-2:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Isolating current transducers and other current measuring devices
I.S. EN 62271-209:2007 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS
BS EN 62271-209:2007 High-voltage switchgear and controlgear Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. Fluid-filled and extruded insulation cables. Fluid-filled and dry-type cable-terminations
EN 62271-209:2007 High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations
EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
HD 637 S1:1999/corrigendum:2005 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
EN 60204-11:2000/corrigendum:2010 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
I.S. EN 60480:2005 GUIDELINES FOR CHECKING AND TREATMENT OF SULPHUR HEXAFLUORIDE (SF[6]) TAKEN FROM ELECTRICAL EQUIPMENT AND SPECIFICATION FOR ITS RE-USE
BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
CEI EN 60265-1 : 2000 INTERRUPTEURS A HAUTE TENSION - PARTIE 1: INTERRUPTEURS POUR TENSIONS ASSIGNEES SUPERIEURES A 1 KV ET INFERIEURES A 52 KV
CEI EN 62155 : 2004 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
CEI UNI EN 45510-2-7 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
EN 50123-7-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-2: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating current transducers and other current measuring devices
BS EN 60044-8:2002 Instrument transformers Electronic current transformers
I.S. EN 50123-1:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - GENERAL
BS EN 50123-1:2003 Railway applications. Fixed installations. D.C. switchgear General
I.S. EN 50123-4:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
CEI EN 62271-209 : 2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 209: CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV - FLUID-FILLED AND EXTRUDED INSULATION CABLES - FLUID-FILLED AND DRY-TYPE CABLE-TERMINATIONS
I.S. EN 50123-7-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES
CEI EN 60044-7 : 2001 INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS
BS EN 50123-7-1:2003 Railway applications. Fixed installations. d.c. switchgear. Measurement, control and protection devices for specific use in d.c. traction systems Measurement, control and protection devices for specific use in d.c. traction systems. Application guide
BS EN 50123-2:2003 Railway applications. Fixed installations. D.C. switchgear D.C. circuit breakers
CEI EN 50123-1 : 2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
CEI EN 60077-4 : 2003 RAILWAY APPLICATIONS - ELECTRIC EQUIPMENT FOR ROLLING STOCK - PART 4: ELECTROTECHNICAL COMPONENTS - RULES FOR AC CIRCUIT-BREAKERS
I.S. EN 61869-1:2009 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
I.S. EN 45510-2-7:2002 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
BS EN 61000-4-18 : 2007 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST
I.S. EN 60204-11:2000 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
UNE-EN 61869-1:2010 Instrument transformers -- Part 1: General requirements
EN 60077-4:2003 Railway applications - Electric equipment for rolling stock - Part 4: Electrotechnical components - Rules for AC circuit-breakers
I.S. EN 50123-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
CEI EN 60044-8 : 2004 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS
BS EN 60470:2001 High-voltage alternating current contactors and contactor-based motor starters
BS EN 60044-7:2000 Instrument transformers Electronic voltage transformers
UNI CEI EN 45510-2-7 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
CEI EN 60480 : 2005 GUIDELINES FOR THE CHECKING AND TREATMENT OF SULPHUR HEXAFLUORIDE (SF6) TAKEN FROM ELECTRICAL EQUIPMENT AND SPECIFICATION FOR ITS RE-USE
I.S. EN 62271-2:2003 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE
BS EN 61264:1999 Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear
I.S. EN 50123-2:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - D.C. CIRCUIT BREAKERS
I.S. EN 50123-7-3:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING VOLTAGE TRANSDUCERS AND OTHER VOLTAGE MEASURING DEVICES
I.S. EN 62155:2003 HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V
EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear
EN 50123-7-3:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-3: Measurement, control and protection devices for specific use in d.c. traction systems - Isolating voltage transducers and other voltage measuring devices
04/30116608 DC : DRAFT JUL 2004 EN 50121-5 - RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 5: EMISSION AND IMMUNITY OF FIXED POWER SUPPLY INSTALLATIONS AND APPARATUS
BS EN 61869-1:2009 Instrument transformers General requirements
BS EN 60480:2004 Guidelines for the checking and treatment of sulphur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use
BS EN 60265-1:1998 Specification for high-voltage switches Switches for rated voltages above 1 kV and less than 52 kV
BS EN 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V
I.S. EN 62271-102:2005 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001 (EQV))
CEI EN 61869-1 : 2010 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
I.S. EN 60077-4:2003 RAILWAY APPLICATIONS - ELECTRIC EQUIPMENT FOR ROLLING STOCK - PART 4: ELECTROTECHNICAL COMPONENTS - RULES FOR AC CIRCUIT-BREAKERS
I.S. HD 637:1999 POWER INSTALLATIONS EXCEEDING 1 KV A.C.
I.S. EN 61958:2001 HIGH-VOLTAGE PREFABRICATED SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - VOLTAGE PRESENCE INDICATING SYSTEMS
EN 62271-2:2003 High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above
EN 61958:2001 High-voltage prefabricated switchgear and controlgear assemblies - Voltage presence indicating systems
EN 50123-7-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 7-1: Measurement, control and protection devices for specific use in d.c. traction systems - Application guide
EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
EN 61869-1:2009 Instrument transformers - Part 1: General requirements
EN 50123-4:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 50123-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers
EN 60044-8:2002 Instrument transformers - Part 8: Electronic current transformers
EN 60480:2004 Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use
EN 50123-3:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 3: INDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES

IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use
IEC 60050-351:2013 International Electrotechnical Vocabulary (IEV) - Part 351: Control technology
EN 60255-23:1996 Electrical relays - Part 23: Contact performance
IEC 60038:2009 IEC standard voltages
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60050-131:2002 International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory
IEC 60947-7-2:2009 Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors
EN 60051-4:1989 Direct acting indicating analogue electrical measuring instruments and their accessories - Part 4: Special requirements for frequency meters
IEC 60730-2-9:2015 RLV Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing controls
IEC 60228:2004 Conductors of insulated cables
EN 61000-4-1:2007 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 61020-4:1991 Electromechanical switches for use in electronic equipement - Part 4: Sectional specification for lever (toggle) switches
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 60050-811:1991 International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction
IEC 60947-4-1:2009+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
EN 60034-1:2010/corrigendum Oct. 2010 ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE
IEC 60073:2002 Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
HD 384.2 : 200S2 INTERNATIONAL ELECTROTECHNICAL VOCABULARY - ELECTRICAL INSTALLATIONS OF BUILDINGS
IEC 60068-2-63:1991 Environmental testing - Part 2: Test methods - Test Eg: Impact, spring hammer.
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 60073:2002 Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators
IEC 60255-21-3:1993 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 3: Seismic tests
IEC 60730-2-13:2017 Automatic electrical controls - Part 2-13: Particular requirements for humidity sensing controls
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60730-2-9:2010 Automatic electrical controls for household and similar use - Part 2-9: Particular requirements for temperature sensing controls
IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60269-2:2013+AMD1:2016 CSV Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
IEC 60051-4:1984 Direct acting indicating analogue electrical measuring instruments and their accessories. Part 4: Special requirements for frequency meters
IEC 60485:1974 Digital electronic d.c. voltmeters and d.c. electronic analogue-to-digital converters
IEC 60947-5-1 : 4.0 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-1: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - ELECTROMECHANICAL CONTROL CIRCUIT DEVICES
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61166:1993 High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers
IEC 61000-4-17:1999+AMD1:2001+AMD2:2008 CSV Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test
IEC 61000-4-12 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-12: TESTING AND MEASUREMENT TECHNIQUES - RING WAVE IMMUNITY TEST
IEC 61810-1:2015 Electromechanical elementary relays - Part 1: General and safety requirements
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
IEC 60056:1987 High-voltage alternating-current circuit-breakers
IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment
IEC 60947-7-1:2009 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
IEC 60269-2-1:2004 Low-voltage fuses - Part 2-1: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to VI: Examples of types of standardized fuses
IEC TR 61000-5-2:1997 Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 2: Earthing and cabling
HD 472 S1:1989/AC:2013 NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS
EN 60255-8:1998 Electrical relays - Part 8: Thermal electrical relays
IEC 61166:1993 High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers
IEC 61810-7:2006 Electromechanical elementary relays - Part 7: Test and measurement procedures
ISO 9002:1994 Quality systems — Model for quality assurance in production, installation and servicing
EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
EN 60947-3:2009/A2:2015 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015)
IEC 60051-2:1984 Direct acting indicating analogue electrical measuring instruments and their accessories. Part 2: Special requirements for ammeters and voltmeters
IEC 60064:1993+AMD1:2000+AMD2:2002+AMD3:2005 CSV Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60721-2-2:2012 Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind
HD 630.2.1 : 200S6 LOW-VOLTAGE FUSES - PART 2-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - SECTIONS 1 TO 5: EXAMPLES OF TYPES OF STANDARDIZED FUSES
HD 323.2.3 : 200S2 BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE
IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
EN 60064:1995/A5:2009 TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR GENERAL LIGHTING PURPOSES - PERFORMANCE REQUIREMENTS
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
EN 60051-5:1989 Direct acting indicating analogue electrical measuring instruments and their accessories - Part 5: Special requirements for phase meters, power factor meters and synchroscopes
EN 60947-4-1 : 2010 AMD 1 2012 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012)
HD 566 : 200S1 THERMAL EVALUATION AND CLASSIFICATION OF ELECTRICAL INSULATION
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60273:1990 Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V
EN 60068-2-17:1994 Environmental testing - Part 2: Tests - Test Q: Sealing
IEC 60051-5:1985 Direct acting indicating analogue electrical measuring instruments and their accessories. Part 5: Special requirements for phase meters, power factor meters and synchroscopes
IEC TS 61000-6-5:2001 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power station and substation environments
IEC 60050-446:1983 International Electrotechnical Vocabulary (IEV) - Part 446: Electrical relays
IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
HD 348 : 200S7 HIGH-VOLTAGE ALTERNATING-CURRENT CIRCUIT-BREAKERS
IEC TR 60943:1998+AMD1:2008 CSV Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals
EN 61000-4-12:2017 Electromagnetic compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60947-4-2:2011 Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters
IEC 60393-1:2008 Potentiometers for use in electronic equipment - Part 1: Generic specification
IEC 60255-5:2000 Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60669-1:2017 Switches for household and similar fixed-electrical installations - Part 1: General requirements
EN 60730-2-1 : 97 AMD 11 2005 AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-1: PARTICULAR REQUIREMENTS FOR ELECTRICAL CONTROLS FOR ELECTRICAL HOUSEHOLD APPLIANCES
EN 60269-2:1995/A2:2002 LOW-VOLTAGE FUSES - SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION)
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEC 60255-21-1:1988 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section One: Vibration tests (sinusoidal)
ISO 9001:2015 Quality management systems — Requirements
IEC 60255-8:1990 Electrical relays - Part 8: Thermal electrical relays
EN 60255-21-1:1995 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 1: Vibration tests (sinusoidal)
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
IEC 60255-23:1994 Electrical relays - Part 23: Contact performance
IEC 60721-2-4:1987+AMD1:1988 CSV Classification of environmental conditions - Part 2-4: Environmental conditions appearing in nature - Solar radiation and temperature
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60059:1999+AMD1:2009 CSV IEC standard current ratings
IEC 61180-1:1992 High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements
IEC 60947-2:2016 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
EN 60947-2:2017 Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
EN 60947-7-1:2009 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS
IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
EN 61000-4-17:1999/A2:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-17: TESTING AND MEASUREMENT TECHNIQUES - RIPPLE ON D.C. INPUT POWER PORT IMMUNITY TEST
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements
EN 60947-4-2:2012 Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters - AC semiconductor motor controllers and starters
HD 243 : S12 GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - INDEX, SURVEY AND COMPILATION OF THE SINGLE SHEETS
IEC 60445:2017 Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 60309-2:1999/A2:2012 PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 2: DIMENSIONAL INTERCHANGEABILITY REQUIREMENTS FOR PIN AND CONTACT-TUBE ACCESSORIES (IEC 60309-2:1999/A2:2012)
EN 60068-2-63 : 1994 ENVIRONMENTAL TESTING - PART 2: TEST METHODS - TEST EG: IMPACT, SPRING HAMMER
IEC 60050-581:2008 International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment
EN 60051-2:1989 Direct acting indicating analogue electrical measuring instruments and their accessories - Part 2: Special requirements for ammeters and voltmeters
CISPR 16-1:1999+AMD1:2002 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
EN 60255-21-3:1995 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 3: Seismic tests
IEC 60309-2:1999+AMD1:2005+AMD2:2012 CSV Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories
EN 61180-1:1994 High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements
EN 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 60050-301:1983 International Electrotechnical Vocabulary (IEV) - Part 301: General terms on measurements in electricity - Part 302: Electrical measuring instruments - Part 303: Electronic measuring instruments
EN 60730-2-13:2008 Automatic electrical controls for household and similar use - Part 2-13: Particular requirements for humidity sensing controls
IEC TR 61000-5-1:1996 Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 1: General considerations - Basic EMC publication
EN 60269-1:2007/A2:2014 LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014)
EN 60309-1:1999/A1:2007/AC:2014 PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60309-1:1999/A2:2012)
EN 60947-7-2:2009 Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductors
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.