• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN ISO 18857-2:2011

Current

Current

The latest, up-to-date edition.

Water quality - Determination of selected alkylphenols - Part 2: Gas chromatographic-mass spectrometric determination of alkylphenols, their ethoxylates and bisphenol A in non-filtered samples following solid-phase extraction and derivatisation (ISO 18857-2:2009)

Published date

09-11-2011

Foreword
Introduction
1 Scope
2 Normative references
3 Principle
4 Interferences
5 Reagents
6 Apparatus
7 Sampling and sample pretreatment
8 Procedure
9 Calibration and analysis of samples
10 Expression of results
11 Test report
Annex A (informative) - Example of a sorbent
Annex B (informative) - Suitable capillary columns
Annex C (informative) - Examples of chromatograms
Annex D (informative) - Performance data
Bibliography

ISO 18857-2:2009 specifies a gas chromatographic-mass spectrometric (GC‑MS) determination of selected alkylphenols, their ethoxylates and bisphenol A in non-filtered samples of drinking, ground, surface, and waste waters following solid‑phase extraction and derivatisation.The lower limit of the working range depends on the matrix, on the specific compound to be analysed and on the sensitivity of the mass spectrometric detection unit. The method is applicable in a working range from 0,005 µg/l to 0,2 µg/l for 4-(1,1,3,3-tetramethylbutyl)phenol (OP), and its mono- (OP1EO) and diethoxylate (OP2EO), from 0,03 µg/l to 0,2 µg/l for 4-nonylphenol (mixture of isomers) (NP), and its mono- (NP1EO) and diethoxylate (NP2EO), and from 0,05 µg/l to 0,2 µg/l for bisphenol A (BPA).Depending on the matrix, the method is also applicable to waste water in a working range from 0,1 µg/l to 50 µg/l for OP, OP1EO, OP2EO and BPA, and from 0,5 µg/l to 50 µg/l for NP, NP1EO and NP2EO. The working ranges are based on experimental work carried out in ruggedness testing. Water samples containing suspended matter at concentrations of more than 500 mg/l and waste water samples are extracted by passing a 100 ml sample through the cartridge.

Committee
CEN/TC 230
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

S.R. CEN/TS 16182:2012 SLUDGE TREATED BIOWASTE AND SOIL - DETERMINATION OF NONYLPHENOLS (NP) AND NONYLPHENOL-MONO- AND DIETHOXYLATES USING GAS CHROMATOGRAPHY WITH MASS SELECTIVE DETECTION (GCMS)
UNI CEN/TS 16182 : 2012 SLUDGE TREATED BIOWASTE AND SOIL - DETERMINATION OF NONYLPHENOLS (NP) AND NONYLPHENOL-MONO- AND DIETHOXYLATES USING GAS CHROMATOGRAPHY WITH MASS SELECTIVE DETECTION (GCMS)
CEN/TS 16182:2012 Sludge treated biowaste and soil - Determination of nonylphenols (NP) and nonylphenol-mono- and diethoxylates using gas chromatography with mass selective detection (GC-MS)

ISO 1042:1998 Laboratory glassware One-mark volumetric flasks
ISO 5667-3:2012 Water quality Sampling Part 3: Preservation and handling of water samples
ISO 5667-1:2006 Water quality Sampling Part 1: Guidance on the design of sampling programmes and sampling techniques
ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
ISO 8466-1:1990 Water quality Calibration and evaluation of analytical methods and estimation of performance characteristics Part 1: Statistical evaluation of the linear calibration function

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.