NF EN 29104 : 1993

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

MEASUREMENT OF FLUID FLOW IN CLOSED CONDUITS - METHODS OF EVALUATING THE PERFORMANCE OF ELECTROMAGNETIC FLOW-METERS FOR LIQUIDS

Superseded date

29-09-2021

Published date

12-01-2013

Committees responsible
National foreword
Methods
Introduction
1 Scope
2 Normative references
3 Definitions
4 General testing procedure
5 Evaluation of the effect of an influence quantity
6 Tests for the evaluation of the effects of other
    influence quantities
Figures
1 Sample calibration showing distribution of test
    points
2 Typical circuit arrangements for upstream gate valve
    tests
3 Examples showing the effects of an upstream gate
    valve on three electromagnetic meters of DN 500
    (based on real data)
4 Annular or segmental obstructions used to determine
    the effects of a disturbance in the inlet flow on
    the response of the flow-meter
5 General test circuit
6 Test of the effect of a) mains frequency common-mode
    voltage (voltage applied between the earth of the
    primary and secondary devices) and b) mains
    frequency voltage between neutral and primary earth
    (voltage applied between earth and mains, if
    practicable)
7 Test of the effect of mains frequency voltage
    between earth and output terminals
8 Test of the effect of a.c. currents on earthed
    connection between primary and secondary devices
9 Test of the effect of series-mode signals at the
    supply frequency
10 Test of the effect of stray currents within the
    liquid
Annex
A Bibliography

Describes the evaluation of the performance of electromagnetic flow-meters for liquids flowing in closed conduits. It specifies a uniform procedure to verify the performance characteristics when the flow-meter is subjected to identified influence quantities and methods of representing the results of performance measurements.

DevelopmentNote
Indice de classement: X10-121. (05/2015)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
I.S. EN 29104:1994 Identical
UNE-EN 29104:1996 Identical
BS EN 29104:1993 Identical
SN EN 29104 : 1994 Identical
UNI EN 29104 : 1994 Identical
EN 29104 : 1993 Identical
ISO 9104:1991 Identical
NBN EN 29104 : 1993 Identical
DIN EN 29104:1993-08 Identical

NFM 60 825 : 2012 ENERGIE NUCLEAIRE - MESURE DE LA RADIOACTIVITE DANS LES EFFLUENTS GAZEUX ET LIQUIDES - ECHANTILLONNAGE DES EFFLUENTS LIQUIDES DANS UN RECIPIENT OU UN EMISSAIRE DE REJET
FD T90 523-2 : 2008 FD WATER QUALITY - SAMPLING GUIDE FOR MONITORING QUALITY OF WATERS IN THE ENVIRONMENT - PART 2: SAMPLING OF WASTEWATER

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.