IEC 61290-3-2:2008
Current
The latest, up-to-date edition.
Optical amplifiers - Test methods - Part 3-2: Noise figure parameters - Electrical spectrum analyzer method
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
21-07-2008
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Symbols, acronyms and abbreviations
4 Apparatus
5 Test specimen
6 Procedure
6.1 Frequency-scanning technique: calibration
6.2 Frequency-scanning technique: measurement
6.3 Selected-frequency technique: calibration and
measurement
6.4 Measurement accuracy limitations
7 Calculation
7.1 Calculation of calibration results
7.2 Calculation of test results for the frequency-scanning
technique
7.3 Calculation of test results for the selected-frequency
technique
8 Test results
Bibliography
IEC 61290-3-2:2008 applies to optical fibre amplifiers (OFA) using active fibres, containing rare-earth dopants, presently commercially available. Establishes uniform requirements for accurate and reliable measurements, of the noise figure, as defined in 3.1.17 of IEC 61291-1, by means of the electricial spectrum analyzer (ESA) method. This technical revision includes updates to specifically address all types of optical amplifiers - not just optical fibre amplifiers. This standard should be read in conjunction with IEC 61290-3 and IEC 61291-1.
Committee |
TC 86/SC 86C
|
DevelopmentNote |
To be read in conjunction with IEC 61290-3 and IEC 61291-1. (01/2003) Stability Date: 2021. (11/2017)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
JIS C 6122-3-2:2006 | Identical |
NEN EN IEC 61290-3-2 : 2008 | Identical |
I.S. EN 61290-3-2:2008 | Identical |
EN 61290-3-2:2008 | Identical |
NF EN 61290-3-2 : 2009 | Identical |
DIN EN 61290-3-2:2009-06 | Identical |
CEI EN 61290-3-2 : 2010 | Identical |
UNE-EN 61290-3-2:2008 | Identical |
BS EN 61290-3-2:2008 | Identical |
PN EN 61290-3-2 : 2009 | Identical |
I.S. EN 61291-1:2012 | OPTICAL AMPLIFIERS - PART 1: GENERIC SPECIFICATION (IEC 61291-1:2012 (EQV)) |
06/30154856 DC : DRAFT AUG 2006 | EN 61291-2 - OPTICAL AMPLIFIERS - PART 2: DIGITAL APPLICATIONS - PERFORMANCE SPECIFICATION TEMPLATE |
09/30205262 DC : 0 | BS EN 61290-4-1 - OPTICAL AMPLIFIERS - TEST METHODS - PART 4-1: GAIN TRANSIENT PARAMETERS - TWO-WAVELENGTH METHOD |
I.S. EN 61290-3:2008 | OPTICAL AMPLIFIERS - TEST METHODS - PART 3: NOISE FIGURE PARAMETERS |
I.S. EN 61290-4-1:2016 | OPTICAL AMPLIFIERS - TEST METHODS - PART 4-1: GAIN TRANSIENT PARAMETERS - TWO-WAVELENGTH METHOD |
EN 61290-5-3:2002 | Optical fibre amplifiers - Basic specification - Part 5-3: Test methods for reflectance parameters - Reflectance tolerance using an electrical spectrum analyser |
IEC 61291-1:2018 | Optical amplifiers - Part 1: Generic specification |
BS EN 61290-3-3:2014 | Optical amplifiers. Test methods Noise figure parameters. Signal power to total ASE power ratio |
BS EN 61291-1:2012 | Optical amplifiers Generic specification |
CEI EN 61291-1 : 2013 | OPTICAL AMPLIFIERS - PART 1: GENERIC SPECIFICATION |
PD IEC/TR 61292-6:2010 | Optical amplifiers Distributed Raman amplification |
BS EN 61290-5-3:2002 | Optical fibre amplifiers. Basic specification. Test methods for reflectance parameters Reflectance tolerance using an electrical spectrum analyser |
I.S. EN 61290-3-3:2014 | OPTICAL AMPLIFIERS - TEST METHODS - PART 3-3: NOISE FIGURE PARAMETERS - SIGNAL POWER TO TOTAL ASE POWER RATIO |
BS EN 61290-4-1:2016 | Optical amplifiers. Test methods Gain transient parameters. Two-wavelength method |
I.S. EN 60728-6:2011 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 6: OPTICAL EQUIPMENT |
I.S. EN IEC 61291-1:2018 | OPTICAL AMPLIFIERS - PART 1: GENERIC SPECIFICATION |
CEI EN 60728-6 : 2012 | CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 6: OPTICAL EQUIPMENT |
BS EN 60728-6:2011 | Cable networks for television signals, sound signals and interactive services Optical equipment |
02/203702 DC : DRAFT APR 2002 | IEC 61292-2 TR - OPTICAL AMPLIFIERS - PART 2: THEORETICAL BACKGROUND FOR NOISE FIGURE EVALUATION USING THE ELECTRICAL SPECTRUM ANALYSER |
BS EN IEC 61281-1:2018 | Fibre optic communication subsystems Generic specification |
07/30163800 DC : 0 | BS EN 61290-3 - OPTICAL AMPLIFIERS - TEST METHODS - PART 3: NOISE FIGURE PARAMETERS |
CEI EN 61290-3-3 : 2014 | OPTICAL AMPLIFIERS - TEST METHODS - PART 3-3: NOISE FIGURE PARAMETERS - SIGNAL POWER TO TOTAL ASE POWER RATIO |
CEI EN 61290-4-1 : 2012 | OPTICAL AMPLIFIERS - TEST METHODS - PART 4-1: GAIN TRANSIENT PARAMETERS - TWO-WAVELENGTH METHOD |
BS EN IEC 61291-1:2018 | Optical amplifiers Generic specification |
EN IEC 61281-1:2018 | Fibre optic communication subsystems - Part 1: Generic specification |
PD IEC TR 61292-2:2003 | Optical amplifier technical reports Theoretical background for noise figure evaluation using the electrical spectrum analyzer |
12/30260284 DC : 0 | BS EN 61290-3-3 - OPTICAL AMPLIFIERS - TEST METHODS - PART 3-3: NOISE FIGURE PARAMETERS - SIGNAL POWER TO TOTAL ASE POWER RATIO |
11/30249050 DC : 0 | BS EN 61291-1 - OPTICAL AMPLIFIERS - PART 1: GENERIC SPECIFICATION |
EN IEC 61291-1:2018 | Optical amplifiers - Part 1: Generic specification |
I.S. EN 61290-5-3:2002 | OPTICAL FIBRE AMPLIFIERS - BASIC SPECIFICATION - PART 5-3: TEST METHODS FOR REFLECTANCE PARAMETERS - REFLECTANCE TOLERANCE USING AN ELECTRICAL SPECTRUM ANALYSER |
IEC 60728-6:2011 | Cable networks for television signals, sound signals and interactive services - Part 6: Optical equipment |
IEC 61290-4-1:2016 | Optical amplifiers - Test methods - Part 4-1: Gain transient parameters - Two-wavelength method |
IEC 61290-3-3:2013 | Optical amplifiers - Test methods - Part 3-3: Noise figure parameters - Signal power to total ASE power ratio |
IEC 61290-3:2008 | Optical amplifiers - Test methods - Part 3: Noise figure parameters |
I.S. EN IEC 61281-1:2018 | FIBRE OPTIC COMMUNICATION SUBSYSTEMS - PART 1: GENERIC SPECIFICATION |
IEC TR 61292-6:2010 | Optical amplifiers - Part 6: Distributed Raman amplification |
15/30318626 DC : 0 | BS EN 61290-4-1 ED. 2.0 - OPTICAL AMPLIFIERS - TEST METHODS - PART 4-1: GAIN TRANSIENT PARAMETERS - TWO-WAVELENGTH METHOD |
BS EN 61290-3:2008 | Optical amplifiers. Test methods Noise figure parameters |
CEI EN 61290-3 : 2010 | OPTICAL AMPLIFIERS - TEST METHODS - PART 3: NOISE FIGURE PARAMETERS |
IEC 61281-1:2017 | Fibre optic communication subsystems - Part 1: Generic specification |
IEC TR 61292-2:2003 | Optical amplifier technical reports - Part 2: Theoretical background for noise figure evaluation using the electrical spectrum analyzer |
EN 61290-4-1:2016 | Optical amplifiers - Test methods - Part 4-1: Gain transient parameters - Two-wavelength method |
IEC 61290-5-3:2002 | Basic specification for optical amplifier test methods - Part 5-3: Test methods for reflectance parameters - Reflectance tolerance test method using electrical spectrum analyzer |
EN 61290-3-3:2014 | Optical amplifiers - Test methods - Part 3-3: Noise figure parameters - Signal power to total ASE power ratio |
EN 61291-1:2012 | Optical amplifiers - Part 1: Generic specification |
EN 60728-6:2011 | Cable networks for television signals, sound signals and interactive services - Part 6: Optical equipment |
EN 61290-3:2008 | Optical amplifiers - Test methods - Part 3: Noise figure parameters |
IEC 60825-2:2004+AMD1:2006+AMD2:2010 CSV | Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS) |
IEC 60728-6:2011 | Cable networks for television signals, sound signals and interactive services - Part 6: Optical equipment |
IEC 60825-1:2014 | Safety of laser products - Part 1: Equipment classification and requirements |
IEC TR 61292-2:2003 | Optical amplifier technical reports - Part 2: Theoretical background for noise figure evaluation using the electrical spectrum analyzer |
IEC TR 61931:1998 | Fibre optic - Terminology |
IEC 60874-1:2011 | Fibre optic interconnecting devices and passive components - Connectors for optical fibres and cables - Part 1: Generic specification |
IEC 61291-1:2012 | Optical amplifiers - Part 1: Generic specification |
IEC 61290-3:2008 | Optical amplifiers - Test methods - Part 3: Noise figure parameters |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.