We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
  • IEC 60068-2-64:2008

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You have already added this standard to your Watchlist.
    Visit My Watchlist to view the full list.

    Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

    Available format(s):  Hardcopy, PDF 1 User, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Superseded date:  11-10-2019

    Language(s):  Spanish, Castilian

    Published date:  29-04-2008

    Publisher:  International Electrotechnical Committee

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Requirements for test apparatus
       4.1 General
       4.2 Basic motion
       4.3 Cross-axis motion
       4.4 Mounting
       4.5 Measuring systems
       4.6 Vibration tolerances
       4.7 Control strategy
       4.8 Vibration response investigation
    5 Severities
       5.1 Test frequency range
       5.2 RMS value of acceleration
       5.3 Shape of acceleration spectral density curve
       5.4 Test duration
    6 Preconditioning
    7 Initial measurements and functional performance test
    8 Testing
       8.1 General
       8.2 Initial vibration response investigation
       8.3 Low-level excitation for equalization prior to
           testing
       8.4 Random testing
       8.5 Final vibration response investigation
    9 Recovery
    10 Final measurements and functional performance
    11 Information to be given in the relevant specification
    12 Information to be given in the test report
    Annex A (informative) Standardized test spectra
    Annex B (informative) Guidance
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 60068-2-64:2008 demonstrates the adequacy of specimens to resist dynamic loads without unacceptable degradation of its functional and/or structural integrity when subjected to the specified random vibration test requirements. Broadband random vibration may be used to identify accumulated stress effects and the resulting mechanical weakness and degradation in the specified performance. This information, in conjunction with the relevant specification, may be used to assess the acceptability of specimens. This standard is applicable to specimens which may be subjected to vibration of a stochastic nature resulting from transportation or operational environments, for example in aircraft, space vehicles and land vehicles. It is primarily intended for unpackaged specimens, and for items in their transportation container when the latter may be considered as part of the specimen itself. However, if the item is packaged, then the item itself is referred to as a product and the item and its packaging together are referred to as a test specimen. This standard may be used in conjunction with IEC 60068-2-47:2005, for testing packaged products. If the specimens are subjected to vibration of a combination of random and deterministic nature resulting from transportation or real life environments, for example in aircraft, space vehicles and for items in their transportation container, testing with pure random may not be sufficient. See IEC 60068-3-8:2003 for estimating the dynamic vibration environment of the specimen and based on that, selecting the appropriate test method. The major changes with regard to the previous edition concern the removal of Method 1 and Method 2, replaced by a single method, and replacement of Annex A with suggested test spectra and removal of Annex C. Also included in this revision is the testing of soft packed specimens.

    General Product Information - (Show below) - (Hide below)

    Committee TC 104
    Development Note Supersedes IEC 60068-2-34, IEC 60068-2-35, IEC 60068-2-36 and IEC 60068-2-37. (03/2001) Stability Date: 2018. (10/2012) NEW CHILD IS ADDED
    Document Type Standard
    Product Note NEW CHILD IS ADDED
    Publisher International Electrotechnical Committee
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    11/30217192 DC : 0 BS EN ISO 4064-2 - WATER METERS INTENDED FOR THE METERING OF COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS
    ISO 14708-1:2014 Implants for surgery Active implantable medical devices Part 1: General requirements for safety, marking and for information to be provided by the manufacturer
    15/30272172 DC : 0 BS EN ISO 13355 - PACKAGING - COMPLETE, FILLED TRANSPORT PACKAGES AND UNIT LOADS - VERTICAL RANDOM VIBRATION TEST
    NF EN 300019 2-4 : 2016 ENVIRONMENTAL ENGINEERING (EE) - ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - PART 2-4: SPECIFICATION OF ENVIRONMENTAL TESTS - STATIONARY USE AT NON-WEATHERPROTECTED LOCATIONS (V2.4.1)
    UNE-EN 50556:2011 Road traffic signal systems
    DIN EN ISO 20072:2013-10 AEROSOL DRUG DELIVERY DEVICE DESIGN VERIFICATION - REQUIREMENTS AND TEST METHODS (ISO 20072:2009)
    OIML R 140 : 2007 MEASURING SYSTEMS FOR GASEOUS FUEL
    CEI EN 60601-1-11 : 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT
    BS EN 60601-1-11:2015 (published 2015-06) Medical electrical equipment General requirements for basic safety and essential performance. Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
    DIN ISO 9022-22 E : 2012 OPTICS AND PHOTONICS - ENVIRONMENTAL TEST METHODS - PART 22: COMBINED COLD, DRY HEAT OR TEMPERATURE CHANGE WITH BUMP OR RANDOM VIBRATION (ISO 9022-22:2012)
    ISO 80601-2-61:2017 Medical electrical equipment Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
    BS EN 62604-1:2015 Surface acoustic wave (SAW) and bulk acoustic wave (BAW) duplexers of assessed quality Generic specification
    12/30266709 DC : 0 BS EN ISO 4064-2 - WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS
    BS EN 50556:2011 ROAD TRAFFIC SIGNAL SYSTEMS
    IEEE 1725 : 2011 RECHARGEABLE BATTERIES FOR CELLULAR TELEPHONES
    NBR ISO 80601-2-12 : 2014 MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS
    04/30031093 DC : DRAFT FEB 2004 ISO 4064-3 - MEASUREMENT OF WATER FLOW IN CLOSED FULLY CHARGED CONDUITS - METERS FOR COLD POTABLE WATER AND HOT WATER - PART 3: TEST METHODS AND EQUIPMENT
    BS EN ISO 20072:2013 AEROSOL DRUG DELIVERY DEVICE DESIGN VERIFICATION - REQUIREMENTS AND TEST METHODS (ISO 20072:2009)
    08/30192448 DC : DRAFT DEC 2008 BS ISO 14708-5 - IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 5: CIRCULATORY SUPPORT DEVICES
    NF EN 50249 : 2003 ELECTROMAGNETIC LOCATORS FOR BURIED PIPES AND CABLES - PERFORMANCE AND SAFETY
    UNI EN ISO 21649 : 2009 NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS